Fuse Holder And No-Fuse Breaker - Robin LG072 Service Manual

Table of Contents

Advertisement

9 - 5 FUSE HOLDER
and
NO-FUSE HOLDER
9 - 5 - 1 FUSE HOLDER
Check that a fuse is in the fuse holder and check its conti-
nuity with a tester. (See Fig. 9-6.) If it carries current, it is
normal.
FUSE HOLDER
If there is no current, take the fuse out and check it for
continuity. If the fuse carries current, the fuse holder
is
faulty. If the fuse carries no current, replace it with a fuse
of the correct capacity, and check the fuse holder again for
continuity.
Fuse capacities are shown in the
table
below.
Fig.
9-6
TESTER
50Hz
60Hz
110V
I
220V
I
230V
I
240V
11ov
I
120v
DC
I
I
I
I
6A
I
3A
I
3A
7A
6A
I
3A
LG072
I
10A
1
10A
4A
4A
10A
8A
~
4A
LG 102
.
LG152
15A
6A
I
6A
.
6A
15A
I
15A
i
LG201
20A
15A
8A
1
8A
8A
;
20A
Table 9
-
6
50Hz
1201240V
!
1 1 Ol220V
1 1 Ol220V
60Hz
1201240V
DC
LG2Ol-D
10A
8 A x 2
:
1 0 A x 2
1 0 A x 2
8 A x 2
"LG301, LG301 D
employ a
no-fuse breaker.
Table 9-
7
9-5-2 NO-FUSE BREAKER
Only the LC301 and
LG301D
have a no-fuse breaker.
Push the power switch off and check continuity. If no cur-
rent flows, it is normal. Then push the power switch on and
check continuity again. If current flows, it is normal.
If the breaker is a two-pole type, the two pairs of terminals
must carry current.
Fig.
9-7
- 3 6 -