16

Technical Specifications

Permissible Operating and
Storage Conditions
Temperature range for operation
according to ISO 7176-9:
Temperature range for storage
according to ISO 7176-9:
Electrical System
Motors
Batteries
Main fuse
Charging device
Output current
Output voltage
Input voltage
Ambient temperature (during
operation)
Storage temperature
Drive wheel tyres
Tyre type
Tyre pressure
Front castor tyres
Tyre type
• -25 ... +50 °C
• -40 ... +65 °C
• 2 x 500 W
• 2 x 12V / 60 Ah, spill-proof / gel
• 80 A
• 8A ± 8%
• 24V nominal (12 cells)
• 200 – 250V nominal
• -25° ... +50°C
• -40° ... +65°C
• 3.00 - 8 pneumatic or puncture proof
• 2.8 bars
• 2.50 - -2.80/4 pneumatic or puncture proof