Important Safety Instructions - Liebert UPS User Manual

6 & 10 kva 208v & 240v
Table of Contents

Advertisement

IMPORTANT SAFETY INSTRUCTIONS

WARNING: Opening or removing the cover may expose you to lethal voltages
within this unit even when it is apparently not operating and the input wiring is
disconnected from the electrical source. Observe all cautions and warnings in
this manual. Failure to do so MAY result in serious injury or death. Refer all
UPS and battery service to qualified service personnel. Do not attempt to
service this product yourself. Never work alone.
1. SAVE THESE INSTRUCTIONS. THIS MANUAL CONTAINS IMPORTANT
SAFETY INSTRUCTIONS.
instructions before installing and operating the Uninterruptible Power System
(UPS). Adhere to all warnings on the unit and in this manual. Follow all
operating and user instructions. Individuals without previous training can
operate this equipment.
2. This product is designed for Commercial/Industrial use only. It is not intended
for use with life support and other designated "critical" devices. Maximum
load must not exceed that shown on the UPS rating label. The UPS is
designed for data processing equipment. If uncertain, consult your dealer.
See Limited Warranty.
3. This UPS is designed for use on a properly grounded (earthed), 208-240
VAC, 50Hz or 60Hz supply, for installation by qualified personnel. A qualified
electrician must review and approve customer supplied wiring, circuit
breakers, intended loads, and verify correct input, output and ground
connections to ensure compliance with technical standards and local
electrical codes of practice. Installation instructions and warning notices only
for use by qualified personnel are located after the UPS operator instructions
in this manual.
4. ELECTROMAGNETIC COMPATIBILITY - The GXT 6 & 10 kVA complies with
the limits for a Class A digital device, pursuant to Part 15 of FCC rules.
These limits provide reasonable protection against harmful interference in a
commercial environment. This device generates, uses, and radiates radio
frequency energy and, if not installed and used in accordance with the
instruction manual, may cause harmful interference to radio communications.
Operating this device in a residential area is likely to cause harmful
interference, which the user must correct at his own expense.
5. Operate the UPS in an indoor environment only in an ambient temperature
range of 0°C to +40°C (32°F to +104°F). Install it in a clean environment, free
from moisture, flammable liquids, gasses, or corrosive substances.
6. This UPS contains no user serviceable parts. The UPS ON/OFF pushbuttons
do not electrically isolate internal parts. Under no circumstances attempt to
gain access internally, due to the risk of electric shock or burn.
Do not continue to use the UPS if the front panel indications are not in
accordance with these operating instructions, or the UPS performance alters
in use. Refer all faults to your dealer.
7. Only trained engineers authorized by Liebert should perform troubleshooting.
To replace batteries, refer all servicing to qualified service personnel.
PROPER DISPOSAL OF BATTERIES IS REQUIRED. REFER TO YOUR
LOCAL LAWS AND REGULATIONS FOR DISPOSAL REQUIREMENTS.
Read all safety, installation, and operating
2

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents