MT VERNON E2 INSERT
B. Clearance To Combustibles, US & Canada
Figure 8.1
A
Side of Outside Skin
B
Vent Pipe to Combustible
C
Cast Side to Side Wall
Built-in Unit - Rear Vent with Outside Air
J
K
Figure 8.2
8
Built-in Unit - Rear Vent
A
Location
Top or Rear Vent
Top or Rear Vent
Top or Rear Vent
3 in
[76mm]
3 in
[76mm]
B
A
Confi guration
Note: In Canada where passage through a
wall or partition of combustible construction is
desired, the installation shall conform to
CAN/CSA-B365.
Through the wall, horizontal termination cap
must be a minimum of 6" (152mm) from the
wall. Approved for mobile home installations.
Must use 3" or 4" (76-102mm) "L" or "PL"
6 in
listed pellet venting or listed double wall pipe
[152mm]
and a Quadrafi re outside air kit (OAK3) in
mobile homes.
3 in
[76mm]
Note:
• Illustrations refl ect typical installations and
•
Illustrations/diagrams are not drawn to scale.
Outside
• Actual installation may vary due to individual
Air
7082-131C
C
Inches
Millimeters
2
51
3
76
6
152
WARNING
Fire Risk.
Comply with all minimum clearances to
combustibles as specifi ed.
Failure to comply may cause house
fi re.
are FOR DESIGN PURPOSES ONLY.
design preference.
June 18, 2014