Clearance To Combustibles, Us & Canada - Quadra-Fire MTVI-E2-MBK Installation Manual

Hide thumbs Also See for MTVI-E2-MBK:
Table of Contents

Advertisement

MT VERNON E2 INSERT
B. Clearance To Combustibles, US & Canada
Figure 8.1
A
Side of Outside Skin
B
Vent Pipe to Combustible
C
Cast Side to Side Wall
Built-in Unit - Rear Vent with Outside Air
J
K
Figure 8.2
8
Built-in Unit - Rear Vent
A
Location
Top or Rear Vent
Top or Rear Vent
Top or Rear Vent
3 in
[76mm]
3 in
[76mm]
B
A
Confi guration
Note: In Canada where passage through a
wall or partition of combustible construction is
desired, the installation shall conform to
CAN/CSA-B365.
Through the wall, horizontal termination cap
must be a minimum of 6" (152mm) from the
wall. Approved for mobile home installations.
Must use 3" or 4" (76-102mm) "L" or "PL"
6 in
listed pellet venting or listed double wall pipe
[152mm]
and a Quadrafi re outside air kit (OAK3) in
mobile homes.
3 in
[76mm]
Note:
• Illustrations refl ect typical installations and
Illustrations/diagrams are not drawn to scale.
Outside
• Actual installation may vary due to individual
Air
7082-131C
C
Inches
Millimeters
2
51
3
76
6
152
WARNING
Fire Risk.
Comply with all minimum clearances to
combustibles as specifi ed.
Failure to comply may cause house
fi re.
are FOR DESIGN PURPOSES ONLY.
design preference.