Connecting Hardwire Devices; Ac Terminals; Hwin1, Hwin2, And Dcout Terminals; Wiring Interior Sirens - GE Euro Simon Installation Instructions Manual

Table of Contents

Advertisement

Note
These terminals cannot pro-
vide both functions simulta-
neously.
Note
The total current available
from the DCOUT terminal is
250 mA at up to 50° C.
Note
Do not install the resistor at
the panel terminals. This
does not provide supervision
of the wire. If you are only
installing an interior siren
and Option 53 is on, you
must connect a 47k resistor
between the HWIN2 and
DCOUT terminals.
7
3. Insert anchors into holes where studs are not present.
4. Feed all wires through wire access areas (see Figure 3).
5. Install all screws and tighten gently.

Connecting Hardwire Devices

The panel has 5 screw terminals located on the upper-right corner of the circuit board (see Fig-
ure 3) for connecting AC power, sirens and/or hardwire detectors.

AC Terminals

A fused terminal block is used for connecting the panel to a mains supply. The terminal block
is pre-wired from the factory to a built-in step-down transformer.

HWIN1, HWIN2, and DCOUT Terminals

These terminals are dual purpose and can be used for either siren or hardwire detector connections.
Sirens
From the factory, these terminals are set up for siren operation with HWIN1 handling interior
sirens (status and alarm sounds), HWIN2 handling exterior sirens (alarm sounds only), and
DCOUT providing the positive (+) voltage.
With Option 53: Hardwire Siren Supervision turned on, sirens connected to HWIN1 and
HWIN2 are supervised and require a 4.7k resistor in the circuit. If either of these terminals is
not used with Option 53 on, you must connect a 47k resistor between the unused terminal and
DCOUT.
Hardwire Detectors
To set up HWIN1 and/or HWIN2 for hardwire detectors, make the required connections as
described under "Wiring Hardwire Detectors," then proceed to the "Programming" section to
add (learn) them into panel memory.

Wiring Interior Sirens

Panel terminal HWIN1 can be used for connecting interior sirens and activates for status and
alarm sounds.
Interior sirens must always be wired with a resistor in the circuit. For circuit supervision which
allows the panel to detect if the siren wire is cut (open), Option 53: Hardwire Siren Supervision
must be turned on (see the "Programming" section).

Hardwire Interior Siren

Connect a hardwire interior siren to the panel using a 4.7k resistor as shown in Figure 4. The
resistor must be connected across the siren wires as close to the siren as possible.
A C
A C
H W I N 2
D C O U T
SIREN
4.7k Resistor
(Locate at siren)
Figure 4. Hardwire Interior Siren with Supervision
H W I N 1
Euro Simon Security System

Advertisement