NA-168VX2/168VG2/148VA2/128VA2/147VB2
12 OPERATING TEST-NO WATER
Method to "Operating Test- No Water"
1. Press the power switch to "OFF".
2. Press and hold both the "Intensive" and"Extra Rinse" buttons with one hand.
3. Press the power switch to "ON".
4. Release your fingers from the buttons and power switch you pressed in step (2) and (3) above.
(Check mode-A shall be carried out with your fingers released.)
5. Press the "Intensive" button within 3 seconds to the desired check contents .(Carry out check B,C,I,G and H)
0
A
1
B
2
C
3
I
4
G1
* On mode NA-168VX2
888
6
7
8
-24-
A