PLANNING YOUR INSTALLATION

MANUFACTURED (MOBILE) HOME INSTALLATION

Freestanding Models – Optima 2 FS and Optima 3 FS
In addition to the standard installation instructions, the
following instructions may be required by local, state or
federal building codes:
• Stove must be permanently bolted to the floor.
• An outside air inlet must be provided for combustion
and be unrestricted while unit is in use. Use a galva-
nized or stainless steel pipe for the duct (the outside
air inlet on the stove is 2" diameter).
• Stove must be permanently electrically grounded to
the steel chassis of the home. The location selected
for ground attachment to the stove must be dedicated
for this purpose.
• See pages 14 through 19 for additional information on
venting requirements.
• Do not install appliance in a sleeping room.
• The structural integrity of the manufactured home
floor, walls, ceiling and roof must be maintained.
NOTE: The grounding of this product, at installation,
must comply with NFPA-70 standards, CSA C22.1 in
Canada, as well as any local codes.
Models – Optima 2 FS and Optima 3 FS
Floor
Chassis
MANUFACTURED (MOBILE) HOME EXHAUST VENT
PIPE INSTALLATION GUIDELINES
Use only listed type "PL" pellet vent pipe. Pipe should
extend at least 3 feet above the part of the roof through
which it passes. The top of the pipe should be at least 2
feet above the highest required elevation of any part of
the manufactured (mobile) home within 10 feet of the
pipe.
If the exhaust vent exits the manufactured (mobile)
home at a location other than the roof, and exits at a
point 7 feet or less above the ground level on which the
manufactured (mobile) home is positioned. A guard or
method of enclosing the pipe shall be provided at the
point of exit for a height of up to 7 feet. The openings, if
any, in this guard shall not allow a 3/4" rod to pass
through. A 1/2" rod could pass through but should not
be able to touch the pipe when inserted through the
opening a distance of 4 inches.
Bolt
Ground to Steel Chassis
PAGE 9