Manufactured (Mobile) Home Installation - Whitfield P/N 775 024M Rev. C Installation And Operation Manual

Freestanding pellet fired stove
Table of Contents

Advertisement

INSTALLATION
REMOVE APPLIANCE FROM PALLET
1. After removing the packaging from the stove, lift the
hopper lid, and remove any pre-packaged items
that were shipped in the hopper. Also open the
door assembly and remove any pre-packaged
items.
2. Using a 3/8" socket or open end wrench, remove
the four bolts from the leg bottoms that secure the
stove to the wooden pallet.
FRONT
Remove the 4 bolts.
INSTALL DOOR HANDLE ONTO DOOR ASSEMBLY
1. Remove door handle from packaging and attach to
door as illustrated below.
Front View of Door Assembly
DOOR
ASSEMBLY
BACK
PALLET

MANUFACTURED (MOBILE) HOME INSTALLATION

Model – Cascade
In addition to the standard installation instructions, the
following instructions may be required by local, state or
federal building codes:
• Stove must be permanently bolted to the floor.
• An outside air inlet must be provided for combustion
and be unrestricted while unit is in use. Use a galva-
nized or stainless steel pipe for the duct. The mini-
mum size for the duct shall be not less than 50% of
the cross sectional area of the flue outlet (the outside
air inlet on the stove is 2" diameter).
• Stove must be permanently electrically grounded to
the steel chassis of the home. The location selected
for ground attachment to the stove must be dedicated
for this purpose.
• See pages 7 through 13 for additional information on
venting requirements.
• Do not install appliance in a sleeping room.
• The structural integrity of the manufactured home
floor, walls, ceiling and roof must be maintained.
NOTE: The grounding of this product, at installation,
must comply with NFPA-70 standards, CSA C22.1 in
Canada, as well as any local codes.
Floor
Chassis
Page 6
Bolt
Floor
Protector
Ground to Steel Chas-
sis

Hide quick links: