Whitfield Advantage Optima 3 FS Installation And Operation Manual page 35

Freestanding and insert pellet fired stoves
Table of Contents

Advertisement

SPECIFICATIONS
- Optima 3 FS
Flue Size
Width, Overall
Depth, Overall
Depth, Overall w / 3" tee
Height
Floor to Rear
Flue Center
Facing Back of Unit,
outside edge on right
to center of rear
flue outlet
Floor to Rear
Outside Air Inlet
Located on center-
line of pedestal back.
Facing Back of Unit
outside edge on right
to center of air inlet
Floor Protection
Requirements
Standard Features
Hopper Capacity
Burn time
Fuse, Control Board
Fuse, Igniter
Heat Input (Max.)
Overall Efficiency
Emissions
Ship Weight
Room Air Blower
Auger Motor
Exhaust Blower
Fastfire Igniter
Options
3" / 76mm Rear
25 7/8"
24 7/8"
30 3/4"
31 3/8"
16 7/8"
5 1/8"
10"
12 15/16"
+ Front and Side: 6"/152mm
Back: Up to 6" / 152mm
Fastfire Self Igniter
Wall Thermostat
(wire included)
70 lbs.
♦ 16-41 hours
5 Amp, 250 volt, 3AG *
6 Amp, 125 volt *
♦ 14,000-38,000 BTU / hr
81%
♦ .9 gr / hr (varies w / size
and type of fuel) EPA ex-
empt
270 lbs.
150 CFM; .8 Amps,
2175 rpm
1 RPM; .4 Amps
95 CFM: 1.0 Amps,
2880 rpm
4.35 Amps,
Nickel or Gold Trim Kits
4" Quick Disconnect
Log Set
8 7/8"
Note: Dimensions shown are approximations only (+/- ¼")
+
Non-combustible thermal rated floor protection must
be used when installed on carpet (see Floor Protection,
page 6). When installed at clearances less than 6",
the floor protector is only required to extend to the
wall.
♦ Fuel delivery and burn times will vary depending
on size and type of fuel used. Estimated heat input
based on fuel value of 8400 BTU per lb.
* Fuses are rated as fast blow.
PAGE 35
BACK VIEW
25 7/8"
5 1/8"
12
15/16"
5 1/8"
SIDE VIEW
30 3/4"
24 7/8"
31 3/8"
16 7/8"

Advertisement

Table of Contents
loading

This manual is also suitable for:

Advantage optima 2 fs

Table of Contents