PLANNING YOUR INSTALLATION
FLOOR PROTECTION - Optima 2 FS
This appliance requires noncombustible floor protec-
tion. If the floor protection is to be stone, tile, brick, etc.,
it must be mortared or grouted to form a continuous
non-combustible surface. If a chimney connector ex-
tends horizontally over the floor, the protection must
cover the floor under the connector and at least 2" to
either side.
A noncombustible floor protector must fully cover the
area beneath the appliance and extend 6" to the front,
6" to the sides, and up to 6" from the back as illus-
trated on this page.
*Note: When installed at clearances less than 6", floor pro-
tection is only required to extend to the wall.
Top View of Model: Optima 2 FS
6"/
153mm
min.
PAGE 5
Up to * 6"/153mm
minimum
Rear
Front
6"/
153mm
min..
6"/
153mm
min.