CAUTION
The fi replace in which the Profi le
30 INS-2 is to be installed must be
thoroughly cleaned if it has been
used to burn wood or synthetic
logs. Have the chimney and all
inside surfaces of the fi replace
brushed and vacuumed so that
no soot, embers, or loose com-
bustion deposits can be drawn
into the heat circulation blower
and blown into the living area.
If any portion of the chimney
system shows signs of structural
or mechanical weaknesses, such
as: cracks, leaky joints, corroded
or warped surfaces, the faulty
portion must be repaired or
replaced prior to installing this
appliance.

MANUFACTURED HOME INSTALLATION

Free-Standing Models – Profi le 20 FS-2 and
Profi le 30 FS-2
In addition to the standard installation instruc-
tions, the following instructions may be required
by local, state or federal building codes:
• The stove must be permanently bolted to
the fl oor.
• An outside air inlet must be provided for
combustion and be unrestricted while unit
is in use. Use a galvanized or stainless steel
pipe for the duct (the outside air inlet on the
stove is 1-5/8" diameter).
• Stove must be permanently electrically
grounded to the steel chassis of the home.
The location selected for ground attach-
ment to the stove must be dedicated for
this purpose. Grounding must comply with
NFPA-70 standards, CSA C22.1 in Canada,
as well as any local codes.
• See Pages 10 through 16 for additional
information on venting requirements.
• Do not install appliance in a sleeping
room.
• The structural integrity of the manufactured
home fl oor, walls, ceiling and roof must be
maintained.
Manufactured Home Exhaust Vent Pipe Instal-
lation Guidelines
Use only "PL" pellet vent pipe listed to UL 641
and ULC S609. The pipe should extend at least
3 feet above the part of the roof through which
it passes. The top of the pipe should be at least
2 feet above the highest required elevation of
any part of the manufactured home within 10
feet of the pipe (see Page 12, Manufactured
Home Chimney Height Requirements).
8
If the exhaust vent exits the manufactured home
at a location other than the roof, and exits at
a point 7 feet or less above the ground level
on which the manufactured home is position
a guard or method of enclosing the pipe shall
be provided at the point of exit for a height of
up to 7 feet. The openings, if any, in this guard
shall not allow a 3/4" rod to pass through. A
1/2" rod could pass through but should not be
able to touch the pipe when inserted through
the opening a distance of 4 inches.
Chassis
Bolt
Floor
Figure 8 - Manufactured Homes

INSTALLATION

Removing Appliance From Pallet
1. After removing the packaging from the
stove, lift the hopper lid, and remove all
prepackaged items that were shipped in
the hopper. Next, open the stove door and
remove all prepackaged items.
2. Using a 7/16" socket or open end wrench,
remove the bolts which secure stove to
pallet. The bolts are located on the underside
of the wooden pallet.
Remove the three bolts from
underneath the pallet.
Figure 9 - Removing from Pallet
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE
Installation Check List
It is strongly recommended that you have an
authorized Lennox Hearth Products dealer
install your stove. If you install your stove
yourself, you should review your installation
plan with an authorized Lennox Hearth Prod-
ucts dealer.
Check list:
Check off each item as you proceed with the
installation process.
Read the ENTIRE stove installation section
fi rst
Read the Insert or Free-Standing section
(whichever applies).
Determine the appropriate measurements
and locations for your installation.
Floor
Protector
Follow the installation directions in this
manual that are applicable to your model
of free-standing stove or fi replace insert.
Be sure to prefi t all items before you install,
fasten, or set up the appliance perma-
nently.
Prior to lighting your appliance:
Review the safety precautions section.
Review the pellet FUEL section.
Review and follow the Operating Instruc-
tions.
Plug power cord connector into correspond-
ing connector on the back of appliance (see
Figures 12 through 16 on Page 10 showing
connector locations).
Note: Profi le 30 INS-2 – Route power cord
behind side surround panel.
After you have begun operation of your
appliance:
Review the routine cleaning / maintenance
information.
Enjoy the warmth from your new Lennox
Hearth Products pellet appliance!
It is important to level the appliance. When
installing the insert model, in some instal-
lations such as a recessed fi rebox fl oor (if
the existing fi replace fl oor is lower than the
hearth), install the 2 leveling bolts (1/4-20 x
3" long) into the threaded holes at the rear
base of the Profi le 30 INS-2. Adjust bolts until
appliance is level.

Advertisement