Danfoss TP7001 User Manual page 25

Tp7001 range electronic 7 day programmable room thermostat
Hide thumbs Also See for TP7001:
Table of Contents

Advertisement

Option 10 - Frost / Thermostat Mode Setting
This feature allows the default frost/thermostat mode
temperature to be set. Press + until Option 10 is
displayed, use Λ or V to select required setting.
GB
Any value between 5.0ºC to 40.0ºC in 0.5ºC steps
Factory Setting is 5.0ºC
Option 11 - Start Up Method
This feature allows the thermostat to start up the
system in three diff erent ways. Press + until Option 11
is displayed, use Λ or V to select required setting.
0 = Normal: Heating is turned up or down at the
programmed times. (Factory Setting)
1 = Optimum Start Control (OSC) (or Comfort Setting): This allows
you to programme the time at which you would like to be up to
the required temperature. The thermostat then calculates how soon
before the required time the heating is turned up. This will vary with
weather conditions ranging from a maximum of 120 minutes to 0
minutes before the programmed event time. This setting must be
used together with option 12 to match the optimiser setting to the
building in which it is installed.
2 = Delayed start (or Economy Setting):
This is an alternative to OSC. Set the event times in the normal way
taking into account the time that the building takes to heat on
an average day. The thermostat monitors switch on time, actual
temperature and wanted temperature and delays the start of the
heating if the actual temperature is close to the programmed
temperature. This setting must be used together with Option 12 to
match the delayed setting to the building in which it is installed.
Danfoss Heating