2.6

Product description

The Logano G201 is a solid fuel boiler and approved for
fueling with coal and wood chunks.
The boiler consists of:
– Air vent [1]
– Ash pan door [2]
– Fuel filler door [3]
– Firing controller [4] with rod and chain
– Aquastat [5]
– Manifold [6] with safety valve and thermometer/
manometer.
Using the firing controller [4], the desired boiler water
temperature is set and limited to this maximum value.
The firing controller [4] is connected to the air vent [1] via
a chain (in the ash pan door) and regulates the airflow of
the boiler. The warmer the boiler becomes, the more the
air vent is closed so that the set boiler water temperature
is not exceeded.
The fuel filler door [3] allows you to fill the ignition cham-
ber with fuel.
The ignition chamber transmits the heat generated to the
heating water.
The ash container is behind the ash pan door [2].
The thermometer/manometer on the manifold [6] displays
the temperature in the boiler and the water pressure.
The jacket is lined with insulation materials and thus pre-
vents radiation loss and stand-by heat losses.
Exhaust flap
The exhaust flap is opened to heat up a cold boiler or in
case of poor flue draft (
Fig. 2 above). This allows hot
flue gas to escape more quickly into the chimney and the
chimney "draws" better.
When the boiler is operating normally and when there is
sufficient flue draft, the exhaust flap is closed (
below). This way, less heat is lost through the chimney.
Logano G201 - Subject to technical modifications.
Information about the appliance
Fig. 1
Logano G201
1
Air vent
2
Ash pan door
3
Fuel filler door
4
Firing controller
5
Aquastat
6
Manifold
Fig. 2
Fig. 2
Exhaust flap (top: open; bottom: closed)
2