Heating Up The Boiler - Buderus Logano G201 Operating Instructions Manual

Solid fuel boiler
Hide thumbs Also See for Logano G201:
Table of Contents

Advertisement

4.4

Heating up the boiler

WARNING: Risk of system damage due to
incorrect operation!
Overfilling the firing chamber with fuel can
cause overheating and damage to the boiler.
V Adjust fuel quantity to the energy absorp-
tion of the heating system
(
Chapter 4.5, page 15).
Important for clean burning in the boiler are
the correct operation of the boiler and a suf-
ficient flue draft for the flue gas system.
V Open the ash pan door.
V Turn the bolt [2] of the front grate counter-clockwise to
the stop.
V Fold the front grate [1] downwards.
V Turn the bolt [2] of the segment plate counter-clock-
wise to the stop.
V Remove the segment plate [1].
V To increase the draft of the boiler, open the exhaust
flap.
Logano G201 - Subject to technical modifications.
Start-up and operation
Fig. 6
Folding the front grate downwards
1
Front grate
2
Bolt
Fig. 7
Removing the segment plate
1
Segment plate
2
Bolt
Fig. 8
Open the exhaust flap
4
13

Advertisement

Table of Contents
loading

Table of Contents