FUNCTION OF CONTROL PANEL

The following functions are available through control panel:.
1. Setting of standby operation: To set a running condition at the start-up.(refer to page 17)
2. Setting of log interval and sending to PC: To set a log interval (page 30) and to send a log date to
PC. (refer to page 25) When this function is used, an optional interface board is necessary. Contact
our sales representative or agent at the time of installation of the optional parts.(refer to page 51)
3. Setting of date and time: To set the date and time shown on the top screen.(refer to page 28)
4. Setting of alarm: To set the high or low temperature alarm(refer to page 19). Also, to set the alarm
delay (refer to page 20).
5. Default setting: To set the default items including LCD back color.(refer to page 27)
6. Alarm test: The test of alarm buzzer, alarm lamp and remote alarm is effective by pressing the
buzzer stop key (BUZZER) for about five seconds during normal operation. Pressing the key again
finishes the alarm test.
1. Running operation (Set):
1-1 Chamber temperature (Temperature): -80
(Refer to page 18)
1-2 High temperature alarm (High Alarm): +10
(Refer to page 19)
1-3 Low temperature alarm (Low Alarm): -10
to page 19)
1-4 Alarm delay time (Alarm Delay): 15 min. (Default setting) (Setting range: 0 -15 min.) (Refer to
page 20)
1-5 Ring back of buzzer (Ring Back): 30 min. (Default setting) (Setting range: 0, 1 – 99 min.) (Refer
to page 21)
1-6 Key lock (Key Lock): 0 (Default setting), 0: Unlock, 1: Lock (Refer to page 22 – 23)
2. Log (Log): When this function is used, an optional interface board is necessary. Contact our sales
representative or agent at the time of installation of the optional parts.
2-1 Log data on past the first (PC 1D) (Refer to page 24)
2-2 All of the log data (PC ALL) (Up to 5 weeks) (Refer to page 25)
2-3 Clear log data (Clear) (Refer to page 25)
3. Various setting (Tools):
3-1 Initialization (Default Setting): When this function from
interface board is necessary.
installation of the optional parts.
3-1-1 LCD Back Color: 1 (Default Setting) (1: Blue、2: White) (Refer to page 27)
3-1-2 DAQ Speed: 0 (Default Setting) (0: 2400、2: 9600(bit/sec)) (Refer to page 27)
3-1-3 DAQ ID: 0 (Default Setting) (0: OFF、1 – 250) (Refer to page 27)
3-1-4 DAQ Mode: 0 (Default Setting) (0: Local、1: Remote) (Refer to page 27)
3-1-5 Remote Alarm: 1 (Default Setting)) 0: OFF、1: Active) (Refer to page 27)
3-1-6 Drive mode (Control: 0 (Default Setting) (0: Normal、1: ECO) (Refer to page 27)
3-2 Date・Time (Date Time):
3-2-1 Date: (YY/MM/DD) (Refer to page 28)
3-2-2 Time: (hh:mm:ss) (Refer to page 28)
3-2-3 Door alarm delay time (Door Delay: 2min. (Default Setting) (Setting range: 0 – 15 min)
(Refer to page 29)
3-2-4 Log Interval: 15 min (Default Setting) (Setting range: 2 – 30 min.) (Refer to page 30)
3-2-5 Comp Delay: 3 min. (Default Setting) (Setting range: 3 – 15 min.) (Refer to page 31)
3-3 Key Lock PW Setting: (Refer to page 32)
After setting, press the menu button (MENU), select "OK" and press the enter key (ENTER). The
setting is memorized.
o
C (Default setting) (Setting range: -50
o
C (Default setting) (Setting range:+5
o
C (Default setting) (Setting range:-5
Contact our sales representative or agent at the time of
15
o
C - -40
3-1-2 to 3-1-4 is used, an optional
o
o
C - -90
C)
o
o
C - +40
C)
o
C) (Refer