Inspection Of Each Board - Furuno FE-700 Service Manual

Echo sounder
Hide thumbs Also See for FE-700:
Table of Contents

Advertisement

3.4 INSPECTION OF EACH BOARD

Board/Unit : MAIN board (02P6236)
Signal
In/Out
FREQ
Output
TX0/TX1
Output
KP
Output
GAIN
Output
IEC61162
Output
TD-A , TD-B
Measuring Points
ANLG Board
J4, #21 and GND
ANLG Board
J4, #29 and GND
J4, #30 and GND
MAIN Board
J6, #3 and J6, #4
ANLG Board
J4, #22 and GND
ANLG Board
J4, #17 and #18
16
3.4 INSPECTION OF EACH BOARD
Measured by
Oscilloscope
50 kHz :
200 kHz :
(L=0 V, H=5 V)
Oscilloscope
TX0
TX1
Changes depending on range setting
1) TX0 and TX1 have
opposite phase each
other.
2) Frequency is equal to the
TX frequency.
Oscilloscope
Changes depending on range setting
5V
Same timing as TX0 and
TX1
Multimeter
Changes according to gain
setting
Setting
Setting
Setting
Oscilloscope
Changes depending on data
Rating/Remarks
H
L
5V
0
: about 1.9 V
5
: about 3.1 V
10
: about 3.8 V
5V
about 1 sec

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents