The flue and engine must be installed before the wall can be lined. Remember that both gas and
electricity are required within the cavity (see, "Gas & Electrical Supplies" on page 12).
IMPORTANT
The framing must be self supporting and not place any load on the engine.
The framing shown is indicative only is not intended to illustrate the construction method. The
installation shows one flue option (using the optional Y-Piece) but does not represent a complete
system.
The appliance should be installed on a solid platform.
Gas and power supply must enter through the left hand end of the engine when viewed from the
open side.
Refer to the next section for notes on external wall installation.
When engine installation is complete, the fitting of cardboard from the packaging material to the
front flanges on both sides of the appliance with some low-tac masking tape will help to protect
the appliance from dust, paint, etc. of subsequent construction drawing into the appliance or
marking the glass.
481
framed using
13mm wall lining
20
mm
max wall lining *
263
over
wall lining
Open Side
(High Output)
Combustion Air
* For wall linings of more
than 13mm a non-combustible
material must be used for at
least 200mm above the fire
Rinnai
250mm stainless steel inner
300mm galvanised outer flue
Note - the Y-piece does not
have to be used and the flue
can be finished using two
200/250 flue
300
25
Min
25
Min
320
Y-Piece refer to Notes on Fluing
in the Installation Guide for more
detail
200mm stainless steel inner
250mm galvanised outer flue
While the Y-Piece can be fitted
directly onto the engine, it is
recommended that 1200mm of
flue is fitted before the Y-piece
244
wall lining
Convetion Air
Glass Side
(Low Output)
Whilst a hearth is not required, it is
recommended that protection be given
to any combustible flooring directly in
front of the fire if installed less than
300mm from the floor.
A
Important Note:
If fire is to be installed on an external wall, an
additional piece of glass is required that is at least
over
25mm larger than the flange of the fire (1350 x 650)
and can be fixed to the fire using an adhesive or
double sided tape rated to at least 120°C.
300
recommended
If a hearth is used, the top
of the hearth must be
flush with the underside of
the fire and should sit at
least 5mm under the fire
17
13mm Wall lining
if installed internally
additional 8mm
depending
on adhesive and
glass thickness
DETAIL A
SCALE 1 : 5
RF1200TW OIM