Heat Controller DMC24DB-1 Owner's Manual
Heat Controller DMC24DB-1 Owner's Manual

Heat Controller DMC24DB-1 Owner's Manual

Wall mounted mini - split system dual-zone, tri-zone air conditioning / heat pump
Hide thumbs Also See for DMC24DB-1:

Advertisement

HEAT CONTROLLER, INC.

Wall Mounted

Mini - Split System
DMC24DB-1, DMH24DB-1
DMC36TB-1, DMH36TB-1
Dual-Zone, Tri-Zone
Air Conditioning / Heat Pump
Important Information
• Please read carefully and thoroughly this manual before operating this unit.
• Contact a qualified sevice technician for installation, repair and maintenance of this unit.
• The appliance is not intended for use by young children or those who require supervision.
• Young children should be supervised to ensure that they do not play with the appliance.

Advertisement

Table of Contents
loading

Summary of Contents for Heat Controller DMC24DB-1

  • Page 1: Wall Mounted

    HEAT CONTROLLER, INC. Wall Mounted Mini - Split System DMC24DB-1, DMH24DB-1 DMC36TB-1, DMH36TB-1 Dual-Zone, Tri-Zone Air Conditioning / Heat Pump Important Information • Please read carefully and thoroughly this manual before operating this unit. • Contact a qualified sevice technician for installation, repair and maintenance of this unit.
  • Page 2: Table Of Contents

    Just a little preventive care on your part can save you a great deal of time and money over the life of your air conditioner. You'll find many answers to common problems in the chart of troubleshooting tips. If you review our chart of Troubleshooting Tips first, you may not need to call for service at all.
  • Page 3: Safety Precautions

    Safety Precautions To prevent the injury of the user or other people and property damage, the following instructions must be followed. Incorrect operation due to ignoring instruction will cause harm or damage. The seriousness is classified by the following indications. This symbol indicates the possibility of death or serious injury.
  • Page 4 8ft(2.4m) • There are sharp moving parts that could cause personal injury. 8ft(2.4m) Do not let the air conditioner run for a long time when the humidity is very high and a door or a window is left open.
  • Page 5 • There is risk of electric shock. Do not insert hands or other objects through the air inlet or outlet while the air conditioner is on. • There are sharp and moving parts that could cause personal injury.
  • Page 6 • It may cause a problem for your neighbors. Operation Do not direct airflow at room occupants. • This could damage your health. 6 Room Air Conditioner Install the drain hose to ensure that water is drained away properly. • A bad connection may cause water leakage.
  • Page 7 Always insert the filter securely. Clean the filter every two weeks or more often if necessary. • A dirty filter reduces the efficiency of the air conditioner and could cause product malfunction or damage. Replace all the batteries in the remote.
  • Page 8: Prior To Operation

    1. Do not touch the metal parts of the unit when removing the filter. Injuries can occur when handling sharp metal edges. 2. Do not use water to clean inside the air conditioner. Exposure to water can destroy the insulation, leading to possible electric shock.
  • Page 9: Operating Instructions

    • The remote control may be stored mounted on a wall. • To operate the room air conditioner, aim the remote control at the signal receptor. • The remote control will operate the air conditioner at a distance of up to 7m(23ft). Operating Instructions...
  • Page 10 Desire temperature For cooling,dehumidification,heating modes it display Destired temperature indicator • Cooling • Dehumidification • Heating 10 Room Air Conditioner Operation indicating lamps : 18 C~30 C(64 F~86 F) : 18 C~30 C(64 F~86 F) : 16~30 C(60 F~86 F) •...
  • Page 11: Remote Control Operation

    Remote Control Operation Controls CANCEL AUTO CLEAN Operation Mode Cooling Operation Auto Operation or Auto Changeover Healthy Dehumidification Operation Heating Operation • Cooling Model( ), Heat Pump Model( 1. START/STOP BUTTON Operation starts when this button is pressed Signal transmitter and stops when the button is pressed again.
  • Page 12: Cooling Operation

    For more fresh feeling, press the Indoor Fan Speed Selector and set CHAOS mode. In this mode, the wind blows like natural breeze by automatically changing fan speed according to the CHAOS logic. 12 Room Air Conditioner Press the Start/Stop button.
  • Page 13: Auto Operation

    Auto Operation DURING AUTO OPERATION: You cannot switch the indoor fan speed. It has already been set by the Fuzzy rule. If the system is not operating as desired, manually switch to another mode. The system will not automatically switch from the cooling mode to the heating mode, or from heating to cooling, then you must set the mode and the desired temperature again.
  • Page 14: Healthy Dehumidification Operation

    During the healthy dehumidification function, the air volume is automatically set according to the algorithm responding to the current room temp. and makes the room condition healthy and comfortable even in the high humidity season. 14 Room Air Conditioner Press the Start/Stop button. The unit will respond with beep sound.
  • Page 15 Heating Operation(Heat pump model only) NATURAL WIND BY THE CHAOS LOGIC For more fresh feeling than other fan speed, press the Indoor Fan Speed Selector and set to CHAOS mode. In this mode, the wind blows like natural breeze by automatically changing fan speed according to the CHAOS logic.
  • Page 16: Jet Cool

    In order to return to the normal cooling/heating mode from the Jet Cool mode, you just press either the operation mode selection button, air volume selection or temp. setting button or the JET COOL button again. 16 Room Air Conditioner Press the Start/Stop button. The unit will respond with beep sound.
  • Page 17 2nd F Operation CANCEL AUTO CLEAN For more details, refer to functions next page. Press the Start/Stop button. The unit will respond with beep sound. Open the door of the Remote Controller and press the 2 button to operate functions printed in blue at bottom of buttons.
  • Page 18: Additional Features

    Check the indicator for A.M. and P.M. Press the Timer Cancel button while aiming Remote Controller at the signal receptor. (The timer lamp on the air conditioner and the display will go out.) with the unit running Delay ON and OFF Timer...
  • Page 19: Vertical Airflow Direction Control

    Always use the remote control to adjust the up/down airflow direction. Manually moving the vertical airflow direction louver by hand could damage the air conditioner. When the unit is shut off, the up/down airflow direction louver will close the air outlet vent of the system.
  • Page 20: Auto Clean

    If you want to stop operation, re-press the button. Cooling Model Operating mode Cooling Indoor FAN Speed High Setting Temperature 22°C(72°F) 20 Room Air Conditioner ON/OFF button Heat pump Model Room Temp. 24°C(76°F) 21°C(70°F) Room Temp. < 24°C(76°F) Room Temp. < 21°C(70°F) Cooling Healthy Dehumidification High 22°C(72°F)
  • Page 21: Auto Restart

    Auto restart In case the power comes on again after a power failure, the unit operates automatically to the previous operating conditions. So there is no need of activating this function by pressing any key or button. In the initial mode, the fan operates at a low speed and the compressor starts about 3 minutes later. As the compressor starts, the fan speed also resumes its previous setting mode.
  • Page 22: Maintenance And Service

    2. Dry in the sunlight for two hours. 3. Re-install the TRIPLE DEODORIZING filter to the original position. TRIPLE DEODORIZING Filter 22 Room Air Conditioner Never use any of the followings: • Water hotter than 40°C(104°F) Could cause deformation and/or discoloration. • Volatile substances Could damage the surfaces of the air conditioner.
  • Page 23: Operation Tips

    When the air conditioner is not going to be used for a long time. When air conditioner is not going to be used for a long time. 1. Operate the air conditioner on Air circulation mode (Refer to page 19) for 2 to 3 hours.
  • Page 24: Troubleshooting

    Maintenance and Service Troubleshooting Check the following points before requesting repairs or service... If the fault persists, please contact your dealer or service center. Case The air conditioner does not operate. The room has a peculiar odor. It seems that condensation is leaking from the air conditioner.
  • Page 25 Specifications and performance data subject to change without notice. HEAT CONTROLLER, INC. 1900 WELLWORTH AVENUE • JACKSON, MICHIGAN 49203 THE QUALITY LEADER IN CONDITIONING AIR P/No.: 3828A22236C...

This manual is also suitable for:

Dmh36tb-1Dmc36tb-1Dmh24db-1

Table of Contents