homexpert evohome Installation & User Manual

Wireless radiator zoning kit

Advertisement

Quick Links

evohome
Wireless Radiator
Zoning Kit
Installation & User Guide

Advertisement

Table of Contents
loading

Summary of Contents for homexpert evohome

  • Page 1 Wireless Radiator Zoning Kit Installation & User Guide...
  • Page 2 Getting the most from your evohome system...
  • Page 3 *Source: Energy Saving Research Unit (ESRU), Strathclyde University 2013 & TACMA 2013 - Energy savings quoted were calculated using a 3 bedroom, 2 level home, located in the UK, modelling a family of 4 over a typical week’s activity, comparing an evohome smart zoning system, with recommended settings, to a system comprising of a simple timer, single non-programmable room thermostat and no Thermostatic radiator valves.
  • Page 4 Getting the most from your evohome system...
  • Page 5: Table Of Contents

    Installation & User Guide Getting the most from your evohome system Follow these instructions to learn more about smart zoning and set up your Radiator Controllers. Before you start Make sure you have an evohome Wireless Heating Controller installed and a Radiator Zoning Kit for each radiator in your home.
  • Page 6: What's In The Box

    Information What’s in the box 1 x Wireless Zoning Radiator Controller 1 x Adaptor pack to fit the majority of radiator valves 2 x AA batteries Radiator Controller overview Adjustment dial Menu button Indicates a manual adjustment from the dial Communication error Manual adjustment has been disabled...
  • Page 7: Set Up Your Radiator Controller

    Set up your Radiator Controller If you are adding one or more Wireless Zoning Radiator Kits to an evohome Connected Pack you need to power up the Radiator Controllers and then bind them to the evohome Controller using the ‘Installation Menu’.
  • Page 8 Rename the zone if required and/ or press the green tick Press RADIATOR VALVE If you want to control the zone temperature with the evohome Controller (which needs to be located in that zone) press YES, otherwise press NO. Monday 27 April...
  • Page 9 To cancel BINDING, select EXIT using You should receive a SUCCESS message on the the adjustment dial evohome Controller (if not go back and re-bind) and confirm with the The name of the allocated zone should button. appear on the Radiator Controller display...
  • Page 10 Set up your Radiator Controller Step 2: Install the Radiator Controller Install the Radiator Controller on the radiator Locate the room (zone) for the radiator controller Slide the locking mechanism You may need to use one of the adaptors to the unlock position supplied with the Remove the adaptor from the bottom Wireless Radiator...
  • Page 11 CHECKING Press the button again to send a test signal to the evohome Controller - The Radiator Controller will display a signal strength bar and a rating from 1 (poor) to 5 (excellent) – 0 means the Radiator Controller has not received a test signal back from the evohome Controller.
  • Page 12: Settings Menu

    Set up your Radiator Controller Advanced settings Settings menu The Radiator Controller has 12 basic settings (parameters) that can be adjusted if required. To enter the settings menu Press the button for approximately 5 seconds until LANGUAGE is displayed Turn the adjustment dial to select the desired parameter (left-hand digit will flash).
  • Page 13 Installation & User Guide Parameter list Parameter Description Available Settings Display language 1 language 1 ... 6 Sets the language of the interface on the display = English* Display backlight = Disabled 2 backlight Sets whether or not the display backlight comes on when = Enabled* the adjustment dial is turned or the button is pressed Auto window open duration...
  • Page 14 Set up your Radiator Controller...
  • Page 15: Using Your Radiator Controller

    Controller The Radiator Controller will operate your smart zone according to the programmed settings from the evohome Controller and you shouldn’t need to make many adjustments at the radiator. There are however some basic adjustments and display information you can do on the Radiator Controller.
  • Page 16: Manual Temperature Override

    To resume the heating schedule you need to set a temperature on the Radiator Controller. When the next set temperature is received from the evohome Controller the Radiator Controller will then follow the programmed schedule.
  • Page 17: Display The Room (Zone) Name

    Installation & User Guide display the room (zone) name To display the room (zone) name on the Radiator Controller Press the button The name of the room (zone) associated will the Radiator Controller will be displayed for a few seconds PRESS onCE Replacing the batteries...
  • Page 18: Automatic Monitoring Functions

    Controller closes the radiator valve. window is displayed on the Radiator Controller and the symbol is displayed on the evohome Controller for that room. When the temperature begins to rise again the Radiator Controller will reopen the radiator valve after 30 minutes (default).
  • Page 19: Emergency Operation

    Installation & User Guide Emergency operation Emergency radiator valve operation If the Radiator Controller is not functioning (i.e. exhausted batteries) you can manually open and close the radiator valve. Manually opening the radiator valve will Slide the locking mechanism only heat the radiator to the unlock position if the boiler is actively providing heat to...
  • Page 20: Troubleshooting

    Radiator Controller and the evohome Controller (Step 3: Wireless Signal Test). Icons are flashing Repeat the binding procedure. Check the power supply to the evohome Controller and the Radiator Controller. Wireless communication Check the wireless communication between the no sync interrupted Radiator Controller and the evohome Controller.
  • Page 21: Technical & Safety Information

    Installation & User Guide Technical & Safety information Type THR92H1002 Protection class IP30 Radio communication ISM (868.0...870.0MHz) RX Class 2 Range: typically 30m within residential buildings Supply voltage Battery type LR6, AA, AM3 Alkaline: 2 x 1.5V Lithium: 2 x 1.5V NiMH: 2 x 1.2V Connection to the radiator M30 x 1.5...
  • Page 23 Installation & User Guide...
  • Page 24 For installation and programming help: 0300 1301299 www.evohome.honeywell.com evosupportuk@honeywell.com Manufactured for and on behalf of the Environmental and Combustion Controls Division of Honeywell Technologies Sàrl, ACS-ECC EMEA, Z.A. La Pièce 16, 1180 Rolle, Switzerland by its Authorised Representative Honeywell Inc.