TOOL STICKERS & TAGS
DANGER
Failure to use hydraulic hose labeled and certified
Failure to use hydraulic hose labeled and certified
as non-conductive when using hydraulic tools on
as non-conductive when using hydraulic tools on
or near electric lines may result in death or
or near electric lines may result in death or
serious injury.
serious injury.
For proper and safe operation read owners manual
For proper and safe operation read owners manual
and mwke sure that you have been properly
and mwke sure that you have been properly
trained in correct procedures required for work
trained in correct procedures required for work
ELECTROCUTION
on or around electric lines.
on or around electric lines.
HAZARD
12412
DANGER DECAL
28322
CE DECAL (CE)
D
30 LPM @ 138 B AR
EHTMA CATEGORY
11207
CIRCUIT TYPE D DECAL (CE)
4-12 GPM / 15-45 LPM
DO NOT EXCEED 2000 PSI/140 BAR
DO NOT EXCEED SPECIFIED FLOW OR PRESSURE. • USE
CLOSED-CENTER TOOL ON CLOSED-CENTER SYSTEM.
• USE OPEN-CENTER TOOL ON OPEN-CENTER SYSTEM. •
CORRECTLY CONNECT HOSE TO TOOL "IN" AND "OUT"
PORTS. IMPROPER HANDLING USE OR MAINTENANCE OF
TOOL COULD RESULT IN A LEAK, BURST OR OTHER TOOL
FAILURE. • CONTACT AT A LEAK OR BURST CAN CAUSE OIL
INJECTIONS INTO THE BODY. • FAILURE TO OBSERVE
THESE PRECAUTIONS CAN RESULT IN SERIOUS PERSONAL
INJURY.
17275
GPM/PRESSURE DANGER DECAL
NOTE
THE INFORMATION LISTED ON
THE STICKERS SHOWN, MUST BE
LEGIBLE AT ALL TIMES.
REPLACE DECALS IF THEY
BECOME WORN OR DAMAGED.
REPLACEMENTS ARE AVAILABLE
FROM YOUR LOCAL STANLEY
DISTRIBUTOR.
The safety tag (p/n
15875) at right is attached
to the tool when shipped
from the factory. Read
and understand the safety
instructions listed on this
tag before removal. We
suggest you retain this tag
and attach it to the tool
when not in use.
25610
RAILROAD HELP DESK DECAL
29083
ROTATION DIRECTION
DECAL
D A N G E R
1. FAILURE TO USE HYDRAULIC HOSE LABELED AND CERTIFIED
AS NON-CONDUCTIVE WHEN USING HYDRAULIC TOOLS
ON OR NEAR ELECTRICAL LINES MAY RESULT IN DEATH
OR SERIOUS INJURY.
BEFORE USING HOSE LABELED AND CERTIFIED AS NON-
CONDUCTIVE ON OR NEAR ELECTRIC LINES BE SURE THE
HOSE IS MAINTAINED AS NON-CONDUCTIVE. THE HOSE
SHOULD BE REGULARLY TESTED FOR ELECTRIC CURRENT
LEAKAGE IN ACCORDANCE WITH YOUR SAFETY DEPART-
MENT INSTRUCTIONS.
2. A HYDRAULIC LEAK OR BURST MAY CAUSE OIL INJECTION
INTO THE BODY OR CAUSE OTHER SEVERE PERSONAL
INJURY.
A DO NOT EXCEED SPECIFIED FLOW AND PRESSURE FOR
THIS TOOL. EXCESS FLOW OR PRESSURE MAY CAUSE A
LEAK OR BURST.
B DO NOT EXCEED RATED WORKING PRESSURE OF HY-
DRAU
LIC HOSE USED WITH THIS
TOOL. EXCESS PRESSURE MAY
CAUSE A LEAK OR BURST.
C CHECK TOOL HOSE COUPLERS AND CONNECTORS DAILY
FOR LEAKS. DO NOT FEEL FOR LEAKS WITH YOUR
I M P O R T A N T
READ OPERATION MANUAL AND
SAFETY INSTRUCTIONS FOR THIS
TOOL BEFORE USING IT.
USE ONLY PARTS AND REPAIR
PROCEDURES APPROVED BY
STANLEY AND DESCRIBED IN THE OPERA-
TION MANUAL.
TAG TO BE REMOVED ONLY BY
TOOL OPERATOR.
SEE OTHER SIDE
SAFETY TAG P/N 15875
(shown smaller then actual size)
7
L
WA
108
28788
MANUAL DECAL (CE)
29530
SOUND POWER
LEVEL DECAL (CE)
4-12 GPM / 15-45 LPM
DO NOT EXCEED 2000 PSI / 140 BAR
DO NOT EXCEED SPECIFIED FLOW OR PRESSURE
USE CLOSED-CENTER TOOL ON CLOSED-CENTER
SYSTEM. USE OPEN-CENTER TOOL ON OPEN-CENTER
SYSTEM. CORRECTLY CONNECT HOSES TO TOOL "IN"
AND "OUT" PORTS. IMPROPER HANDLING, USE OR OTHER
MAINTENANCE OF TOOL COULD RESULT IN A LEAK, BURST
OR OTHER TOOL FAILURE. CONTACT AT A LEAK OR BURST
CAN CAUSE OIL INJECTION INTO THE BODY. FAILURE TO
OBSERVE THESE PRECAUTIONS CAN RESULT IN SERIOUS
PERSONAL INJURY.
03788
GPM DECAL
Model No.
IW12
08012
IW12 NAME TAG (US & CE)
D A N G E R
D DO NOT LIFT OR CARRY TOOL BY THE HOSES. DO
NOT ABUSE HOSE. DO NOT USE KINKED, TORN OR
DAMAGED HOSE.
3. MAKE SURE HYDRAULIC HOSES ARE PROPERLY CONNECTED
TO THE TOOL BEFORE PRESSURING SYSTEM. SYSTEM
PRESSURE HOSE MUST ALWAYS BE CONNECTED TO TOOL
"IN" PORT. SYSTEM RETURN HOSE MUST ALWAYS BE
CONNECTED TO TOOL "OUT" PORT. REVERSING CONNEC-
TIONS MAY CAUSE REVERSE TOOL OPERATION WHICH CAN
RESULT IN SEVERE PERSONAL INJURY.
4. DO NOT CONNECT OPEN-CENTER TOOLS TO CLOSED-CEN-
TER HYDRAULIC SYSTEMS. THIS MAY RESULT IN LOSS OF
OTHER HYDRAULIC FUNCTIONS POWERED BY THE SAME
SYSTEM AND/OR SEVERE PERSONAL INJURY.
5. BYSTANDERS MAY BE INJURED IN YOUR WORK AREA. KEEP
BYSTANDERS CLEAR OF YOUR WORK AREA.
6. WEAR HEARING, EYE, FOOT, HAND AND HEAD PROTEC-
TION.
7. TO AVOID PERSONAL INJURY OR EQUIPMENT DAMAGE, ALL
TOOL REPAIR MAINTENANCE AND SERVICE MUST ONLY BE
PERFORMED BY AUTHORIZED AND PROPERLY TRAINED
PERSONNEL.
I M P O R T A N T
READ OPERATION MANUAL AND
SAFETY INSTRUCTIONS FOR THIS
TOOL BEFORE USING IT.
USE ONLY PARTS AND REPAIR
PROCEDURES APPROVED BY
STANLEY AND DESCRIBED IN THE OPERA-
TION MANUAL.
TAG TO BE REMOVED ONLY BY
TOOL OPERATOR.
SEE OTHER SIDE
Stanley Hydraulic Tools
3810 SE Naef Road
Milwaukie, Oregon USA
15-45 LPM / 4-12 GPM
140 BAR / 2000 PSI