Position Sensor Abnormality - Daikin Super multi NX E Series Service Manual

Hide thumbs Also See for Super multi NX E Series:
Table of Contents

Advertisement

SiBE121135_A

7.14 Position Sensor Abnormality

H6
Error Code
Outdoor Unit LED
A
∗ LED5 is equipped only on the 5-room model.
Display
Method of Error
A compressor start-up failure is detected by checking the compressor running condition through
the position detection circuit.
Detection
Error Decision
Conditions
Supposed
Causes
Service Diagnosis
j
i
i
h
h
1
2
3
4
If the error repeats, the system is shut down.
Reset condition: Continuous run for about 5 minutes without any other error
Disconnection of the compressor relay cable
Defective compressor
Defective outdoor unit PCB
Start-up failure caused by the closed stop valve
Input voltage is outside the specified range.
h
5
Troubleshooting for Outdoor Unit
218

Advertisement

Table of Contents
loading

Table of Contents