Stove Installation

SAFETY NOTICE:
Please read this entire manual before you install and use your new
room heater. Failure to follow instructions may result in property
damage, bodily injury, or even death. Contact local building or fire
officials about restrictions and installation inspection requirements
in your area.

Planning The Installation

We suggest that you have an authorized Travis Industries dealer install your stove. If you install the
stove yourself, your authorized dealer should review your plans for installation.
Check with local building officials for any permits required for installation of this stove and notify your
insurance company before proceeding with installation.
Preparation for Installation
Check for damage to the exterior of the stove (dents should be reported, scratches can be fixed by
applying touch up paint).
Check the interior of the firebox (replace cracked firebrick and make sure baffle is in place).
The stove can be lightened by removing the firebricks and baffle. (pg 33) - replace before operation.
Stove Installation Considerations
The table below details the six most common types of installations and the considerations for each
type. Alternative methods of installation are available if they comply with local building codes.
Installation Type
Standard Ceiling with a Factory Built Chimney
(Page 14)
Cathedral Ceiling with a Factory Built Chimney
(Page 14)
Exterior Factory Built Chimney
(Page 15)
Hearth Stove Positive Connection
(Page 15)
Hearth Stove Direct Connection
(Page 16)
Interior Masonry Chimney
(Page 16)
Travis Industries
(for qualified installers only)
Considerations
• Requires ceiling and roof penetration
• Provides best draft
• Cathedral style chimney support required
• Provides best draft
• Uses two elbows to route chimney outside
• Exterior chimney is hidden from the room
• Elbows reduce draft
• Optional exterior chase reduces cold air blockage
• Utilizes existing masonry or zero clearance (metal) chimney
• Provides good draft due to full reline
• Easier to clean than direct or horizontal hearth stove
• Utilizes existing masonry or zero clearance (metal) chimney
• Requires construction of a "block-off plate"
• Draft reduced due to elbows & chimney cross section
• Utilizes existing masonry chimney (not approved for zero
clearance (metal) fireplaces)