P13 [EXP2]
Pin no.
1
Input signal spare 1
2
Input signal spare 2
3
Input signal spare 3
4
Input signal spare 4
5
Input signal spare 5
Cutter
6
signal
7
Feed PM overcurrent signal
Work
8
signal
9
+55V relay input signal
10
+55V voltage watch signal
11
-
12
-
13
0V
14
0V
15
0V
16
0V
17
-
18
-
19
-
20
-
21
Cutter return signal
22
Cutter signal
23
Cutter signal
24
Spare solenoid 1
25
Spare solenoid 2
26
Spare solenoid 3
Signal name
home
position
sensor
clamp
PM
overcurrent
6. ELECTRIC COMPONENTS AND SOFTWARE
Probable symptoms due to poor contact
• The feed home position and work clamp home position can
not be found.
• The feed mechanism and work clamp mechanism do not
operate.
• One of error E-06 and E-07 is displayed.
• Cutter does not operate.
• Error E-08 is displayed.