Rating Plate; B-Vent Specifics - Model Gs60; Chimney Installation - Napoleon GDS60N Installation And Operating Instrictions

Natural gas propane gas
Table of Contents

Advertisement

4.7

RATING PLATE

MODEL NATURAL GAS/GAZ NATURAL
DIRECT VENT
TOP VENT REAR VENT
0-4500
35,000
21,000
24,500
#35
MANIFOLD PRESSURE: 3.5 INCHES W.C. (NG) / 10 INCHES W.C.
(LP)
PRESSION AU COLLECTEUR: 3.5" (GN) / 10" (PG) D'UNE COL-
ONNE DÉAU
MIN SUPPLY PRESSURE: 4.5" W.C. (NG) / 11" (LP)
PRESSION D'ALIMENTATION MIN: 4.5" (GN) / 11" (PG) D'UNE
COLONNE D'EAU
MAX. SUPPLY PRESSURE: 7" W.C. (NG) / 13" W.C. (LP)
PRESSION D'ALIMENTATION MAX: 7" (GN) / 13" (PG) D'UNE
COLONNE D'EAU
FOR USE WITH GLASS DOORS CERTIFIED WITH THIS UNIT ONLY.
UTILISER AVEC LES PORTES VITREES HOMOLOGUEES SEULE-
MENT AVEC CETTE UNITE.
WARNING: DO NOT ADD ANY MATERIAL TO THE APPLIANCE,
WHICH WILL COME IN CONTACT WITH THE
FLAMES, OTHER THAN THAT SUPPLIED BY THE
MANUFACTURER WITH THE APPLIANCE.
MODEL CS600/GS60
APPROVED FOR BEDROOM, & BEDSITTING ROOM INSTALLATION. HOMOLOGUE POUR INSTALLATION DANS UNE CHAMBRE A
COUCHER, & UN STUDIO. THIS APPLIANCE MUST BE INSTALLED USING AN ADAPTER KIT GS-150KT. CET APPAREIL DOIT ETRE
INSTALLE EN UTILISANT UN ENSEMBLE ADAPTATEUR GS-150KT.
INSTALLER: It is your responsibility to check off the appropriate box on the rating plate according to
the model, venting and gas type of the unit.
For rating plate location, see "DIMENSIONS" section.
4.8

B-VENT SPECIFICS - MODEL GS60

4.8.1 CHIMNEY INSTALLATION

A CHIMNEY VENTING THIS APPLIANCE SHALL NOT VENT ANY SOLID FUEL BURNING APPLIANCE.
"A" VENT - SOLID
FUEL WOOD BURNING
CHIMNEY & VENT
CONNECTOR
NorthlineExpress.com
CERTIFIED UNDER: CSA 2.33-2000, ANSI Z21.88-2000 VENTED GAS FIREPLACE HEATER AS A DIRECT VENT
AND CSA2.22-M98,ANSI Z21.50-1998 VENTED GAS FIREPLACE AS A B-VENT. HOMOLOGUE SELON LES
NORMES: CSA 2.33-2000, ANSI Z21.88-2000 FOYER DE CHAUFFAGE AU GAZ AVEC EVACUATION EN TANT
QU'UNE EVACUATION DIRECTE ET CSA2.22-M98,ANSI Z21.50-1998 FOYER AU GAZ AVEC EVACUATION
EN TANT QU'UN EVENT "B".
NOT FOR USE WITH SOLID FUEL
UN COMBUSTIBLE SOLIDE NE DOIT PAS ETRE UTILISE AVEC CET APPAREIL
B-VENT
GDS60N
GS60N
CDVS600N
CDVS600N
0-4500
0-4500
ALTITUDE (FT/PI) ELEVATION
*
21,000
35,000
INPUT (BTU/H) ALIMENTATION
*
12,000
21,000
REDUCED INPUT (BTU/H) ALIMENTATION REDUITE
*
14,700
OUTPUT (BTU/H) RENDEMENT
#45
#35
ORIFACE
*
WHEN VENTING OFF THE REAR OF THE UNIT AND TERMINATING HORIZONTALLY
OPTIONALBLOWER KIT / ENSEMBLE DE
VENTILATEUR FACULTATIF: GS64-KT
AVERTISSEMENT: N'AJOUTEZ PAS A CET APPAREIL AUCUN
MATERIAU DEVANT ENTRER EN CONTACT AVEC LES FLAMMES
AUTRE QUE CELUI QUI EST FOURNI AVEC CET APPAREIL PAR
LE FABRICANT.
MINIMUM CLEARANCE TO COMBUSTIBLE MATERIAL / DEGAGE-
MENTS MINIMAUX DES MATERIAUX COMBUSTIBLES:
A
B
C
20" TO CEILING FROM STOVE TOP
1" TO DIRECT VENT AND B-VENT / L'EVACUATION DIRECTE &
L'EVACUATION B
6" TO C-VENT/ A L'EVACUATION C
20" ENTRE LE DESSUS DU FOYER ET LE PLAFOND
ELECTRICAL RATING/CLASS: 115V 1.5AMP 60HZ
(LINER NEEDED
IF INSIDE
DIAMETER IS 6"
OR LARGER)
SINGLE WALL
OR "B" VENT
http://www.northlineexpress.com
MODEL CDVS600/GDS60 APPROVED FOR BEDROOM, BATHROOM & BEDSIT-
TING ROOM INSTALLATION. SUITABLE FOR MOBILE HOME INSTALLATION IF
INSTALLED IN ACCORDANCE WITH THE CURRENT STANDARD CAN/CSA Z240MH
SERIES GAS EQUIPPED MOBILE HOMES, IN CANADA OR IN THE UNITED
STATES THE MANUFACTURED HOME CONTRUCTION AND SAFETY STANDARD,
TITLE 24 CFR, PART 3280. WHEN THIS US STANDARD IS NOT APPLICABLE USE
THE STANDARD FOR FIRE SAFETY CRITERIA FOR MANUFACTURED HOME
INSTALLATIONS, SITES AND COMMUNITIES, ANSI/NFPA 501A.
HOMOLOGUE POUR INSTALLATION DANS UNE CHAMBRE A COUCHER, UNE
MODEL PROPANE/PROPANE MODÈLE
SALLE DE BAIN ET UN STUDIO. APPROPRIE POUR INSTALLATION DANS UNE
B-VENT
DIRECT VENT
MAISON MOBILE SI SON INSTALLATION CONFORME AUX EXIGENCES DE LA
NORME CAN/CSA Z240MH SERIE DE MAISONS MOBILES EQUIPEES AU GAZ,
GS60P
GDS60P
EN VIGUEUR AU CANADA OU AUX ETATS-UNIS DE LA NORME DE SECURITE
CS600P
CDVS600P
ET DE CONSTRUCTION DE MAISONS MANUFACTUREES, TITRE 24 CFR,
REAR VENT TOP VENT
SECTION 3280. DANS LE CAS OU CETTE NORME D'ETATS-UNIS NE PEUT
ETRE APPLIQUEE, SE REFERER A LA NORME RELATIVE AU CRITERE DE
MESURES DE SECURITE CONTRE L'INCENDIE POUR LES INSTALLATIONS
0-4500
0-4500
0-4500
DANS LES MAISONS MANUFACTURES, LES SITES ET LES COMMUNAUTES,
*
31,500
21,000
31,500
ANSI/NFPA 501A.
*
AFUE: 64%
22,000
13,000
22,000
*
MINIMUM AND MAXIMUM HORIZONTAL VENT LENGTHS ARE 25 INCHES AND 20
14,700
22,050
FEET RESPECTIVELY FOR TOP VENTED UNITS AND 13 INCHES AND 20 FEET
#53
#55
#53
RESPECTIVELY FOR REAR VENTED UNITS. LES LONGUEURS HORIZONTALES
MINIMALE ET MAXIMALE SONT 25 POUCES ET 20 PIEDS RESPECTIVEMENT
POUR UN EVACUATION VERTICALE ET 13 POUCES ET 20 PIEDS RESPECTIVE-
MENT POUR UN EVACUATION HORIZONTALE.
THE APPLIANCE MUST BE VENTED USING THE APPROPRIATE NAPOLEON
VENT KITS. SEE OWNERS INSTALLATION MANUAL FOR VENTING SPECIFICS.
PROPER REINSTALLATION AND RESEALING IS NECESSARY AFTER SERVICING
THE VENT-AIR INTAKE SYSTEM.
L'APPAREIL DOIT EVACUER SES GAZ EN UTILISANT L'ENSEMBLE D'EVACUATION
PROPRE A NAPOLEON. REFERER AU MANUEL D'INSTALLATION DE PROPRI-
ETAIRE POUR L'EVACUATION PRECISE. IL EST IMPORTANT DE BIEN REIN-
6"
STALLER ET RESCELLER L'EVENT APRES AVOIR ASSURE LE MAINTIEN DU
6"
SYSTEME DE PRISE D'AIR.
2"
SERIAL NUMBER
NO. DE SERIE
WOLF STEEL LTD BARRIE, ON CANADA
WARNING
!
MASONRY CLAY LINED
CHIMNEY + VENT
CONNECTOR
(NO NEW LINER
NEEDED IF OLD
LINER DIAMETER
IS 4-5")
SINGLE WALL
OR "B" VENT
GDS/CDVS60
MADE IN CANADA / FABRIQUE AU CANADA
W385-0459
"B" VENT
LIQUID FUEL
GAS BURNING
CHIMNEY