VENT TERMINAL CLEARANCES

INSTALLATIONS
CANADA
A
12"
B
12"
C
12" *
D
18" **
E
12" **
F
0"
0" ***
G
2" ***
H
3'
I
3'
J
12"
K
6'
L
7' ‡
M
12" ††
N
16"
O
2' †*
*
Recommended to prevent condensation on windows and thermal breakage
**
it is recommended to use a heat shield and to maximize the distance to vinyl clad soffi ts.
***
The periscope requires a minimum 18 inches clearance from an inside corner.
****
This is a recommended distance. For additional requirements check local codes.
3 feet above if within 10 feet horizontally.
A vent shall not terminate directly above a sidewalk or paved driveway that is located between two single family dwellings and serves both dwellings.
††
Permitted only if the veranda, porch, or deck is fully open on a minimum of two sides beneath the fl oor.
†*
Recommended to prevent recirculation of exhaust products. For additional requirements check local codes.
NOTE: Clearances are in accordance with local installation codes and the requirements of the gas supplier.
NorthlineExpress.com
U.S.A.
12"
Clearance above grade, veranda porch, deck or balcony.
9"
Clearance to windows or doors that open.
12" *
Clearance to permanently closed windows.
Vertical clearance to ventilated soffi ts located above the terminal within a horizontal distance of 2' from
18" **
the centerline of the terminal.
12" **
Clearance to unventilated soffi t.
0"
Clearance to an outside corner wall.
0" ***
Clearance to an inside non-combustible corner wall or protruding non-combustible obstructions (chimney, etc.).
2" ***
Clearance to an inside combustible corner wall or protruding combustible obstructions (vent chase, etc.).
Clearance to each side of the centerline extended above the meter / regulator assembly to a maximum
3' ****
vertical distance of 15'.
3' ****
Clearance to a service regulator vent outlet.
9"
Clearance to a non-mechanical air supply inlet to the building or a combustion air inlet to any other appliance.
3' †
Clearance to a mechanical air supply inlet.
7' ****
Clearance above a paved sidewalk or paved driveway located on public property.
12" ****
Clearance under a veranda, porch, deck or balcony.
16"
Clearance above the roof.
2' †*
Clearance from an adjacent wall including neighbouring buildings.
http://www.northlineexpress.com
13
12.1
W415-0788 / 05.15.09
Toll-Free 1-866-667-8454

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Gs60nGs60pGds60p