To Outdoor Unit; Install All Power, Interconnecting Wiring; And Piping To Indoor Unit; Remote Control Installation - Payne PA13A/ PW3CA Installation Instructions Manual

High - wall duct - free split systems
Table of Contents

Advertisement

INSTALL ALL POWER, INTERCONNECTING
WIRING, AND PIPING TO INDOOR UNIT.
1. Run interconnecting piping and wiring from outdoor unit to
indoor unit.
2. Run interconnecting cable through hole in wall (outside to
inside).
3. Lift indoor unit into position and route piping and drain
through hole in wall (inside to outside). Fit interconnecting
wiring into back side of indoor unit.
4. Put upper claw at back of indoor unit on upper hook of
Mounting Plate, move indoor unit from side to side to see
that it is securely hooked.
5. Open front cover of indoor unit and remove field wiring ter-
minal block cover.
6. Pull interconnecting wire up from back of indoor unit and
position in close to the terminal block on indoor unit.
7. Push lower part of indoor unit up on wall, then move in-
door unit from side to side, up and down to check if it is
hooked securely. (See Fig. 14.)
Fig. 14 --- Indoor Unit Installation
208/230-1-60
From outdoor unit
to indoor unit
Barrier between
high and low voltage
Upper hook
Lower hook
A07347a
Panel
Control Box Cover
18k & 24k
Terminal block
L1 L2
S
G
Control:
Pulse DC between outdoor
unit and indoor unit with a
potential AC voltage shock hazard.

To outdoor unit

Fig. 15 --- Control and Power Wiring on Indoor Unit
8. Connect wiring from outdoor unit per connection diagram
(see Fig. 13 and Fig. 15).
9. Replace field wiring cover and close front cover of indoor
unit.
10. Connect refrigerant piping and drain line outside of indoor
unit.
Refer to Fig. 11 for proper installation of flare
connections. Complete pipe insulation at flare connection
then fasten piping and wiring to the wall as required. Com-
pletely seal the hole in the wall.
NOTE:
For applications where gravity cannot be used for
drainage, a condensate pump accessory is available. Consult the
condensate pump Installation Instructions for more information.

REMOTE CONTROL INSTALLATION

Mounting Bracket (if installed on the wall)
1. Use the two screws supplied with control to attach Mount-
ing Bracket to wall in location selected by customer and
within operating range.
2. Install batteries in Remote Control.
3. Place Remote Control into remote control Mounting Brack-
et.
4. For remote control operation, refer to the unit Owner's
Manual.
9k & 12k
Terminal block of indoor unit
1
2
3
4
12v DC from outdoor unit
35v DC from
outdoor to indoor
To Outdoor Unit
10
to indoor unit
A07349a

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pa13n/ pw3cnPh13a/ pw3ha hpPh13n/ pw3hn hp

Table of Contents