Payne PA13A/ PW3CA Installation Instructions Manual page 8

High - wall duct - free split systems
Table of Contents

Advertisement

INSTALL ALL POWER AND INTERCONNECTING WIRING TO OUTDOOR UNITS
1. Mount outdoor power disconnect.
2. Run power wiring from main box to disconnect per NEC
and local codes.
3. Remove field wiring cover from unit by loosening screws.
4. Remove caps on conduit panel.
5. Connect conduit to conduit panel. (See Fig.12 )
6. Properly connect both power supply and control lines to ter-
minal block per the connection diagram for the appropriate
unit capacity and voltage. (See Fig. 13, pg. 9.)
7. Ground unit in accordance with NEC and local electrical
codes.
8. Use lock nuts to secure conduit.
9. Reinstall field wiring cover.
ELECTRICAL DATA
OPERATING
UNIT
VOLTAGE
SIZE
MAX/MIN
VOLTS--- PH--- HZ
009
127/104
115 ---1 ---60
012
012
018
253/187
208/230 ---1 ---60
024
Outdoor unit
Terminal Block
Fig. 12 --- Field Wiring
COMPRESSOR
OUTDOOR FAN
RLA
LRA
FLA
7.5
40
0.69
9.9
47
5.2
21
0.38
7.3
32.6
0.78
9.7
34.8
0.62
!
EQUIPMENT DAMAGE HAZARD
Failure to follow this caution may result in equipment
damage or improper operation.
S Be sure to comply with local codes while running wire
from indoor unit to outdoor unit.
S Every wire must be connected firmly. Loose wiring may
cause terminal to overheat or result in unit malfunction.
A fire hazard may also exist. Therefore, be sure all wiring
is tightly connected.
S No wire should be allowed to touch refrigerant tubing,
compressor or any moving parts.
S Disconnecting means must be provided and shall be
located within sight and readily accessible from the air
conditioner.
S Connecting cable with conduit shall be routed through
hole in the conduit panel.
Conduit panel
G
Conduit
INDOOR FAN
HP
W
VOLTS
0.102
23
35 DC
0.116
36
35 DC
0.224
53
208/230 ---1 ---60
0.218
100
8
CAUTION
A07455
MCA
FLA
HP
W
1.1
0.034
20
12
1.18
0.044
25
15
1.18
0.044
25
9
0.26
0.075
31
11
0.39
0.112
50
14
MAX
FUSE/CB
AMP
20
25
15
20
25

Hide quick links: