Framing Specifications - Superior DRT63STTEN Installation And Operation Instructions Manual

Superior drt63 see through direct vent gas fireplaces
Table of Contents

Advertisement

INNOVATIVE HEARTH PRODUCTS • SEE-THROUGH DIRECT-VENT GAS FIREPLACES (DRT63STTEN/P) • INSTALLATION INSTRUCTIONS

FRAMING SPECIFICATIONS

Framing should be constructions of 2x4 or larger lumber.
A
B
in
52-1/16
47-5/16
(mm)
(1322)
(1202)
Dimension B is from fireplace base to top framing member.
Dimension C is from fireplace base to centerline of horizontal vent pipe.
Minimum vent framing: 2 ft vertical vent and one 90° elbow. For other
venting configurations, see Step 3, INSTALL VENTING SYSTEM.
1/2-inch board for platform (shown in gray).
Dimension E is a 6-inch clearance from fireplace base to outdoor
surface (e.g., deck, patio, lanai) that is required as a moisture barrier
(not a combustible clearance) on outdoor side only.
16
(406)
6-1/2
(165)
Inches
(millimeters)
B
Figure 12
C
D
E
75-1/2
26-5/16
6
(1918)
(668)
(152)
13
(330)
C
D
A
INDOOR SIDE
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
16
(406)
6-1/2
(165)
Inches
(millimeters)
B
E
*For indoor/outdoor installations, the control side
of the fireplace must be installed on the indoor side.
13
(330)
C
1-1/2
(38)
A
OUTDOOR SIDE*
13