  • Page 2: Table Of Contents

    CONTENTS SOCIABLE REMARK SOCIABLE REMARK When using this air conditioner in the European countries, the following Sociable remark......................2 informations must be followed: SAFETY PRECAUTIONS DISPOSAL: Do not dispose this product as unsorted municipal waste. Collection of such waste separately for special treatment is necessary. Warning ........................3 Caution ........................4 It is prohibited to dispose of this appliance in domestic household waste.
  • Page 3: Safety Precautions

    SAFETY PRECAUTIONS SAFETY PRECAUTIONS To prevent injury to the user or other people and property damage, the following instructions must be followed. Incorrect operation due to ignoring of instructions may cause harm or damage. CAUTION The seriousness is classified by the following indications. This symbol indicates the possibility of death or serious injury.
  • Page 4: Operating Instructions

    OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS Indicator Lights on Display panel Parts names Auto indicator: NOTE:The display panel of the indoor This indicator illuminates when the air Indoor unit unit you purchased may be look like conditioner is in AUTO operation. NOTE: The indoor unit you purchased would like one of the following. There is a slightly one of the following: Timer indicator: difference on front panel and display window, but the features are the same.
  • Page 5: Operating Temperature

    OPERATING INSTRUCTIONS OPERATING INSTRUCTIONS NOTE: This manual does not include Remote Controller Operations, see the Airflow direction control <<Remote Controller Instruction>> packed with the unit for details. Adjust the air flow direction properly otherwise, it Operating temperature might cause discomfort or cause uneven room temperatures.
  • Page 6: How The Air Conditioner Works

    OPERATING INSTRUCTIONS CARE AND MAINTENANCE How the air conditioner works Care and maintenance AUTO operation When you set the air conditioner in AUTO mode, it will SLEEP operation 7 hours timer off automatically select cooling, heating(cooling/heating Cleaning the Grille, Case and Remote Controller models only), or fan only operation depending on what Turn the system off before cleaning.
  • Page 7: Operation Tips

    OPERATION TIPS CARE AND MAINTENANCE The following events may occur during normal operation. 4. Remove the Air Freshening Filter from its support 1. Protection of the air conditioner. frame (on some models). Compressor protection (The optional filter include :Plasma Dust Collector/ The compressor can't restart for 3 minutes after it stops.
  • Page 8: Troubleshooting Tips

    TROUBLESHOOTING TIPS OPERATION TIPS Troubleshooting Tips 7. Dripping water may generate on the surface of the indoor unit when cooling in a high relatively humidity (relative humidity higher than 80%). Adjust the horizontal louver to Stop the air conditioner immediately if one of the following faults occur. Disconnect the the maximum air outlet position and select HIGH fan speed.
  • Page 9 After the fi rst year, with respect to this Limited Warranty, NAPOLEON® may, at its discretion, fully discharge all obligations with respect to this warranty by refunding to the original warranted purchaser the wholesale price of any warranted but defective part(s).
  • Page 11 CONTENTS 3. Set the starting & stopping time 3.1 Push the TIMER ON button, the remote controller will show TIMER ON, the last set time for START operation and the Remote Controller Specification..........signal "h" will be shown on the DIGITAL display area. You Performance Features------------------------------------------------------- are now ready to readjust the TIMER ON to start the operation.
  • Page 12 Remote Controller Specification TEMP Button : Push this button to decrease the indoor temperature setting. Model RG51M5/(C)EU TEMP Button : Push this button to increase the indoor temperature setting . Rated Voltage 3.0V(Dry batteries LR03 2) MODE Selection Button: Each time the button is pressed, the Lowest Voltage of CPU 2.0V operation mode is shifted in the direction of the arrow:...
  • Page 13 TIMER OFF Button: Press this button to initiate the auto-off time ON/OFF Indicator: This symbol appears when the unit is turned sequence. Each press will increase the auto-timed setting in 30 on by the remote controller, and disappear when the unit is minutes increments.
  • Page 14 AUTOMATIC OPERATION DRY Operation Switch on the power and the OPERATION indication lamp on the 1. Push the MODE button to select DRY. display panel of the indoor unit starts flashing, and turns off after 2. Push the TEMP button to set the desired temperature within flashes for 6 times.
  • Page 16 CONTENTS SAFETY PRECAUTIONS Warning ............................2 Caution ............................2 INSTALLATION INSTRUCTIONS Selecting installation place.......................3 Accessories .............................4 Indoor unit installation........................5 Outdoor unit installation ........................7 REFRIGERANT PIPE CONNECTION Refrigerant pipe connection ......................8 ELECTRICAL WORK Electrical work ..........................9 AIR PURGING Air purging with vacuum pump ......................11 Safety and leakage check ......................13 TEST RUNNING Test running ..........................13...
  • Page 17: Safety Precautions

    SAFETY PRECAUTIONS Read the follow SAFETY PRECAUTIONS carefully before installation. Electrical work must be installed by a licensed electrician. Be sure to use the correct rating of the power plug and main circuit for the model to be installed. Incorrect installation due to ignoring of the instruction will cause harm or damage. The seriousness is classified by the following indications.
  • Page 18: Installation Instructions

    INSTALLATION INSTRUCTIONS Selecting installation place Select an installation location which is rigid and strong enough to support or hold the unit, and select a location for easy maintenance. Read completely, then follow step by step. Indoor unit Do not expose the indoor unit to heat or steam. Select a place where there are no obstacles in front or around the unit.
  • Page 19: Accessories

    INSTALLATION INSTRUCTIONS Accessories Number Name of Accessories Q ty Installation Plate Clip Anchor (depending on models) Self-tapping Screw A ST3.9X25 (depending on models) Seal(For cooling & heating modles only) Drain Joint(For cooling & heating modles only) 6.35 Connecting Liquid side Parts you must purchase.
  • Page 20: Indoor Unit Installation

    INSTALLATION INSTRUCTIONS Indoor unit installation Correct orientation of Installation Plate 1. Fit the Installation Plate 1. Fit the installation plate horizontally on structural parts of the wall with spaces around the installation plate. 2. If the wall is made of brick, concrete or the like, drill eight (8) 5mm diameter Fig.4 holes in the wall.Insert Clip anchor for...
  • Page 21 INSTALLATION INSTRUCTIONS 3. Connective Pipe and Drainage Installation Drainage 1. Run the drain hose sloping downward. Do not install the drain hose as Do not put the end of illustrated in Fig.7. Do not block water flow by a rise. drain hose into water.
  • Page 22: Outdoor Unit Installation

    INSTALLATION INSTRUCTIONS 5. Piping and wrapping Bundle the tubing, connecting cable, and drain hose with tape securely, evenly as shown in Indoor unit Ponding box Fig.12 Because the condensed water from rear of the Connective indoor unit is gathered in ponding box and is Pipe room cable piped out of room.
  • Page 23: Refrigerant Pipe Connection

    REFRIGERANT PIPE CONNECTION Settlement of outdoor unit Anchor the outdoor unit with a bolt and Air inlet 10 or 8 tightly and horizontally on a concrete or rigid mo unt. Air inlet Mounting dimensions Outdoor unit dimensio n mm(WxH xD) A(mm) B(mm) 780x540x250...
  • Page 24: Electrical Work

    ELECTRICAL WORK Flare nut C: Putting nut on Remove flare nuts attached to indoor and outdoor unit, then put them on pipe/tube having completed burr removal.(not possible to put them on after flaring work) Copper tube D: Flaring work Firmly hold copper pipe in a die in the dimension shown in the table below.
  • Page 25 ELECTRICAL WORK Minimum norminal cross-sectional area of conductors: Rated current Nominal cross-sectional area of appliance (mm ) 0.75 >3 and <6 >6 and <10 >10 and <16 >16 and <25 NOTE: The cable size and the current of the fuse or switch are determined by the maximum current indicated on the nameplate which located on the side panel of the unit.
  • Page 26 ELECTRICAL WORK Power supply Warning cord Be sure to comply with local codes while running the wire from the indoor unit to the outdoor unit. Power supply Every wire must be connected firmly. 208-230V~60Hz No wire should be allowed to touch refrigerant tubing, the compressor Special branch circuit breaker or any moving parts.
  • Page 27: Air Purging

    AIR PURGING CAUTION CAUTION CAUTION CAUTION After the confirmation of the above conditions, prepare the wiring as follows: 1) Never fail to have an individual power circuit specifically for the air conditioner. As for the method of wiring, be guided by the circuit diagram posted on the inside of control cover.
  • Page 28 AIR PURGING When relocate the unit to another place, perform evacuation using vacuum pump. Refrigerant Indoor Make sure the refrigerant added into the air Outdoor unit unit conditioner is liquid form in any case. Gas side (Not applicable to the units adopt freon R22 ) Liquid side Caution in handling the packed valve Packed valve...
  • Page 29: Safety And Leakage Check

    TEST RUNNING Safety and leakage check Electrical safety check Perform the electric safe check after completing installation: 1. Grounding work After finishing grounding work, measure the grounding resistance by visual detection and grounding resistance tester. Make sure the grounding resistance is less than 4 . 2.