Table 5-11
ServerNet I Panic Messages
Messages
ship_init: Unsupported revision
of the SAIL ASIC detected
CIN=0xnnnnnnnn
SHIP_INTCAUSE_QIP7 already
set
The PLX_ABORT_ACTIVE bit is
set (shipintr())
bte_memreserve: insufficient
physically contiguous memory
intr_memreserve: insufficient
physically contiguous memory
initSail: Insufficient memory for
Interrupt State Block dump
continued
Description
Indicates that an SPA was
found, but the SAIL ASIC on it is
not a recognized revision. The
driver recognizes revisions A
and B of the SAIL ASIC;
however, B is the only revision
supported by Compaq ProLiant
Clusters for SCO UnixWare 7.
This interrupt line is being used
to help flush the SAIL ASIC
register values to memory.
When it is about to be used, it
must not already be set. If it is
set, a software or hardware
error has occurred.
Indicates that the PLX chip
aborted a PCI operation. A
previous SPA read or write
operation has been aborted.
This condition could lead to
unreported data loss or
corruption, so SPA operations
are halted with a PANIC.
These messages display during
initialization and indicate that
not enough memory is available.
Troubleshooting 5-25
User Action
Replace the SPA with a version
containing revision B of SAIL
ASIC (SPA 1.5 revision E).
Reboot the node into the cluster.
Run offline diagnostics. If the
SPA passes diagnostics, reboot
the node into the cluster. If the
SPA fails diagnostics, replace
the SPA.
Check memory utilization and
distribution in the kernel
tunables. If possible, take crash
dump for analysis by product
support personnel.
continued