Table 5-3
Solving Node-to-Node Communication Problems
Problem
Bad packets or ServerNet I
barrier errors reported
Intermittent ServerNet
Advanced Interface Logic
(SAIL) freeze, link level
self-check errors, or
performance degradation
continued
Possible Cause
SPA is defective
ServerNet I board installed in
the wrong slot
Defective or uncertified PCI
board
Troubleshooting 5-9
Action
Cluster Membership Service (CLMS)
master (the active root node) is unable
to communicate with a node during
startup or normal operation.
If a node does not join the cluster, verify
that the SPA is functioning on that node
using the SVU as described in Chapter 3
of this guide.
If all nodes have joined the cluster,
verify ServerNet I functionality by using
the ServerNet I graphical monitor or the
ServerNet I command line diagnostic
(spam). See the spam(1M) man page for
additional information.
Replace the SPA if necessary.
Install the ServerNet I board into slot 1.
For more information on the certified
server listing see the Compaq High
Availability website at
http://www.compaq.com/highavailability
Identify the PCI board that overuses the
PCI bus, hampering SPA operation.
Remove the offending PCI board.