Konica Minolta bizhub C550 User Manual page 304

Network scanner operations
Hide thumbs Also See for bizhub C550:
Table of Contents

Advertisement

Network Settings
Parameter
Server Capacity
E-Mail TX (SMTP) screen 5/5
Parameter
SSL Setting
Port Number
(SSL)
Port No.
SMTP Detail screen (displayed by touching [Detail Setting])
Parameter
SMTP Authentication
POP Before SMTP Au-
thentication
POP Before SMTP Time
!
Detail
If the POP and SMTP servers are different, the POP server must notify the
SMTP server when the POP server is logged on to. Therefore, if the time
specified for "POP Before SMTP Time" is too short, it may not be possi-
ble to send e-mail.
1
Touch [5 Network Setting] in the Administrator Settings screen.
For details on displaying the Administrator Settings screen, refer to
"Displaying the Administrator Settings screen" on page 3-7.
2
Touch [7 E-Mail Settings] in the Network Settings screen.
C550
Description
Specify the maximum capacity that the SMTP server can receive
per e-mail message. To change the setting, press the [C] (clear)
key, and then use the keypad to type in the desired setting. (Range:
1 to 100 Mbyte) To apply no limit, touch [No Limit].
Description
In order to apply SSL/TLS encryption to communications between
this machine and the SMTP server, select "SMTP over SSL" or
"Start TLS".
Specify the port number if "Start TLS" was selected. To change the
setting, touch [Input], press the [C] (clear) key, and then use the
keypad to type in the desired port number. (Range: 1 to 65535)
Specify the port number used with SSL communications if "SMTP
over SSL" was selected. To change the setting, touch [Input],
press the [C] (clear) key, and then use the keypad to type in the de-
sired port number. (Range: 1 to 65535)
Description
Select whether or not SMTP authentication is used. Touching [ON]
displays a screen for entering SMTP authentication information.
For details, refer to "SMTP Authentication" on page 4-81.
Select whether or not POP Before SMTP authentication is used.
Specify when POP Before SMTP authentication is used. To
change the setting, press the [C] (clear) key, and then use the key-
pad to type in the desired setting. (Range: 0 to 60 seconds)
4