E n t d A 0 2 2 - 4 0 6 3 1
R c v d A 0 2 2 - 4 0 6 4 1
Zn ZT
RC
In: L
10 03 10
RF: 1s
PROGRAM ALPHA?
0 = NO 1 = YES
0
E N TE R Z N N U M.
( 0 0 = Q U I T)
1 1
∗ ∗ ∗ ∗ 58 EXPERT PROGRAMMING MODE
SET TO CONFIRM?
0 = NO 1 = YES
Zn ZT RC HW: RT
01 09
10
EL
1
Zn ZT
RC IN: L
10 00
10 RF –
Zn ZT
RC IN: L
10
00 10 RF 1
10 INPUT S/N:
L
A XXX- XXX
Zn ZT P RC In
L
10 03 1 10 RF: 1s

WIRELESS KEY PROGRAMMING TEMPLATES

This procedure programs the wireless keys, but a key is not active for arming/disarming until it is assigned to a user number (see
System Operation section, assigning attributes command in the Installation Instructions).
TEMPLATE ?
1–6
1
L
01
02
03 04
T
23
22
21 23
ENTER START ZONE
00 = QUIT
36
If the serial number transmitted does not match the serial number entered, a display similar to the one
shown appears. If the loop number does not match, it will also be displayed.
If so, activate the loop input or button on the transmitter once again. If a match is not obtained (i.e., summary
display does not appear), press the [#] key twice and then enter (or transmit) the correct serial number.
[∗] to continue
If the serial number transmitted matches the serial number entered, the keypad will beep 3 times
and a summary display will appear, showing that zone's programming. Note that an "s" indicates
that a transmitter's serial number has been enrolled.
[∗] to accept the zone information and continue
If you want to program descriptors for the zone now, enter 1 (yes) and refer to the *82 Descriptor
Programming section for procedures.
To program descriptors later, enter 0 (no).
[∗] to continue
If 0 (No) was entered at the Program Alpha prompt, the system will return you to the ZONE NUMBER
prompt. Repeat these steps for each zone in the system.
When all zones have been programmed, enter 00 as the zone number to quit.
[∗] to continue
(press ∗ ∗ ∗ ∗ 58 while in Data Programming mode)
We recommend that you select "yes" to confirm the programming of every transmitter.
If selected, a prompt appears after entering the serial and loop numbers to confirm each transmitter)
A summary screen will appear, showing zone 1's currently programmed values.
Enter the zone number being programmed, then press [∗]. In this example, zone 10 is being entered
(see Zone Number prompt in *56 Menu Mode for zone numbers).
[D] = for assigning wireless key programming templates (see Wireless Key Programming Templates section
below); lets you choose from a series of preset templates for easy programming of wireless key zones
00 = quit (when all zones have been programmed, press "00" to quit this menu mode)
[∗] to continue
A summary screen with the selected zone's current programming appears.
Begin programming zone information as follows:
Enter Zone Type (ZT; see Zone Types listed in *56 Menu Mode "Zone Type" prompt), Report Code (RC), and
Input Device Type (IN)* sequentially (Loop Number (L) is entered at the next prompt).
• Use the [A] (Advance) and [B] (Back) keys on the keypad to move the cursor within the screen.
• Use the [C] key to copy the previous zones attributes.
* If HW (hardwired) or AW (Auxiliary) is entered for Input Device Type, the display will be similar to the
prompt shown, except that HW or AW will be under "IN".
Press [∗] to save the programming and continue. If needed, press the [#] key to back up without saving.
For wireless devices (input types RF, UR, BR), continue to the serial number/loop number prompt.
For wired devices, return to the initial summary screen prompt to begin programming the next zone.
Manually enter the serial number (found on the transmitter label), by typing digits in the "X" locations, using
the [A] (advance) or [B] (back) keys as required.
OR
Transmit two open/close sequences. If using a button-type transmitter, press and release the button twice,
but wait about 4 seconds before pressing the button the second time.
If you want to copy the previous zone's serial number, press the [C] key.
Press [∗] to advance to the loop number, then enter loop number.
Press [∗] to accept the existing serial and loop number and continue to the "Confirm" prompt described in
*56 Menu mode above.
If necessary, press [#] to back up and re-enter or edit the serial number.
If the serial number transmitted matches the serial number entered, the keypad will beep 3 times and a
summary display will appear, showing the programmed information for that zone.
Press [∗] to begin programming the next zone. See first "Summary Screen" prompt paragraph.
Enter desired template number 1–6 (see chart on previous page).
Press [#] if you want to return to *58 Menu mode Summary Screen.
If necessary, press [#] to back up and re-enter template number.
Press [∗] to continue to template display.
The selected template is displayed.
Top line of display represents loop numbers, bottom line represents zone type assigned for each loop.
Press [∗] to accept template and continue.
The system will search for the highest available consecutive 4-zone group (the four zones in the case of the
5804 and 5804BD), and display the lowest zone number of the group.
If you want to start at a different zone, enter the zone desired, and press [∗]. If that zone number is
displayed, the system has the required number of consecutive zones available, beginning with the zone you
entered. If not, the system will again display a suggested zone that can be used.
If the required number of consecutive zones is not available at all, the system will display "00".
Press [∗] to accept and continue.
WWW.DIYALARMFORUM.COM
(press the [D] key from *58 Menu mode Summary Screen display)