Where noted, certain fields have special settings when used with the
for easy identification).
SIA Guidelines: Notes in certain data fields give instructions for programming the VISTA-10P for False Alarm Reduction.
NOTE: Entry of a number other than one specified will give unpredictable results. Values shown in brackets are factory defaults.
∗ ∗ ∗ ∗ 20
Installer Code
4 digits, 0–9. Can perform all system functions except cannot disarm
unless it is used to arm system.
∗ ∗ ∗ ∗ 21
Quick Arm Enable
0 = no quick arm; 1 = allow quick arm (with [#] key)
∗ ∗ ∗ ∗ 22
RF Jam Option
0 = no RF Jam detection
1 = send RF Jam report upon detection of RF jamming signal
UL: must be 1 if wireless devices are used
∗ ∗ ∗ ∗ 23
Quick (Forced) Bypass
0 = no quick bypass UL: must be "0"
1 = allow quick bypass (code + [6] + [#] )
∗ ∗ ∗ ∗ 24
RF House ID Code
00 = disable all wireless keypad usage
01–31 = house ID for 5827, 5827BD or 5804BD keypad
∗ ∗ ∗ ∗ 26
Chime By Zone
0 = no (chimes on fault of any entry/exit or perimeter zone when
chime mode on);
1 = use zone list (chimes on fault of specific zones programmed in
relay zone list 3 when Chime mode on; use *81 Menu mode to
select zones)
∗ ∗ ∗ ∗ 28
Access Code For Phone Module
00 = disable; UL: must be "00" for UL Commercial Burg. inst.
1st digit: enter 1–9; 2nd digit: enter # + 11 for " ✱ ", or # + 12 for "#".
∗ ∗ ∗ ∗ 29
Long Range Radio Output
0 = not using LORRA; 1 = using LORRA output
∗ ∗ ∗ ∗ 31
One Audible Alarm Per Zone
0 = unlimited sounding; 1 = one alarm sounding per zone
VISTA-10PSIA:
If "0" selected, "alarm sounding per zone" will be the
same as the "number of reports in armed period" set in field *93 (1 if
one report, 2 if 2 reports, unlimited for zones in zone list 7).
∗ ∗ ∗ ∗ 32
Fire Alarm Sounder Timeout
0 = sounder stops at timeout programmed in field ∗33
1 = no sounder timeout UL: must be "1" for fire install.
∗ ∗ ∗ ∗ 33
Alarm Sounder (Bell) Timeout
0 = none; 1 = 4 min; 2 = 8 min; 3 = 12 min; 4 = 16 min;
UL: For residential fire alarm installation, must be set for a minimum
of 4 min (option 1); for UL Commercial Burglary installations, must
be minimum 16 min (option 4)
∗ ∗ ∗ ∗ 34
Exit Delay
00 - 96 = 0 - 96 secs; 97 = 120 secs
SIA Guidelines: minimum exit delay is 45 seconds
UL: see inst. instr. for requirements.
VISTA-10PSIA:
45 - 96 = 45 - 96 secs; 97 = 120 secs
NOTE: Entries less than 45 will result in a 45-second delay.
∗ ∗ ∗ ∗ 35
Entry Delay #1
(zone type 01)
00 - 96 = 0 - 96 secs; 97 = 120 secs; 98 = 180 secs; 99 = 240 secs
SIA Guidelines: minimum entry delay is30 seconds
VISTA-10PSIA:
30-96 = 30 - 96 secs; 97 = 120 secs; 98 = 180 secs; 99 = 240 secs
NOTE: Entries less than 30 will result in a 30-second delay.
For UL Residential Burglary Alarm installations, must be set for a
maximum of 30 seconds; entry delay plus dial delay should not
exceed 1 min. For UL Commercial Burglar Alarm, total entry delay
may not exceed 45 seconds.
∗ ∗ ∗ ∗ 36
Entry Delay #2
(zone type 02)
See *35 Entry Delay 1 above for entries.

DATA FIELD PROGRAMMING FORM

[4112]
|
|
|
[0]
[0]
[0]
[00]
|
[0]
[00]
|
[0]
[0]
[0]
[1]
[60]
|
[30]
|
[30]
|
WWW.DIYALARMFORUM.COM
VISTA-10PSIA
(indicated by heavy borders and reverse type throughout
∗ ∗ ∗ ∗ 37
Audible Exit Warning
0 = no; 1 = yes; SIA Guidelines: must be enabled (enter 1)
VISTA-10PSIA:
Feature always enabled; field does not exist.
∗ ∗ ∗ ∗ 38
Confirmation Of Arming Ding
0 = no ding
1 = confirmation ding after arming system
2 = ding after arming from RF button or RF keypad only
UL: must be "1" for UL Commercial Burglar Alarm inst.
∗ ∗ ∗ ∗ 39
Power Up In Previous State
0 = always power-up in a disarmed state
1 = assume the system status prior to power down
UL: must be "1" SIA Guidelines: must be enabled (enter 1)
VISTA-10PSIA:
Feature must be enabled (enter 1).

DIALER PROGRAMMING

Enter the number of digits shown. Do not fill unused spaces. Enter 0–9; #+11
for ' ✱ '; #+12 for '#'; #+13 for a 2-second pause. If fewer than the maximum
digits entered, exit the field by pressing [✶]. The next field number is displayed.
∗ ∗ ∗ ∗ 40
PABX Access Code
Enter up to 6 digits. To clear entries, press ✱40✱. If call waiting used, enter its
cancel digits "∗ (#+11) 70" plus "# + 13" (pause).
NOTE: 1. The call waiting disable feature cannot be used on a PABX line.
2. Using call waiting cancel on a non-call waiting line will prevent
successful communication to the central station.
VISTA-10PSIA:
If call waiting is used, enter call waiting disable digits as
described above, and also set Call Waiting Disable option in field *91.
∗ ∗ ∗ ∗ 41
Primary Phone No.
| | | | | | | | | | | | | | | | | | |
∗ ∗ ∗ ∗ 42
Second Phone No.
| | | | | | | | | | | | | | | | | | |
Enter up to 20 digits. To clear entries, press ✱ 41 ✱ or ✱ 42 ✱
respectively .
NOTE: Entry of a number other than one specified will give
unpredictable results.
For fields *43- *44: Enter 0–9; #+11 for B; #+12 for C; #+13 for D; #+14 for E;
#+15 for F. Enter [ ✱ ] as the fourth digit if a 3-digit account number (for 3+1
dialer reporting format) is used. Enter 0 as the first digit of a 4-digit account
number for Nos. 0000-0999. Exit field by pressing ✱ (and press next field
number) if only 3 digits are used. E.g., For Acct. B234, enter:
#+11| 2 | 3 | 4
∗ ∗ ∗ ∗ 43
Primary Subs. Acct. No.
| | | /
| | | | |
depending on selection in *48 Report Format. See box above for
entries. To clear entries, press * 43 *.
∗ ∗ ∗ ∗ 44
Secondary Subs. Acct. No.
| | | /
| | | | |
clear, press * 44 * .
∗ ∗ ∗ ∗ 47
Phone System Select
DIALING
NOT On WATS LINE
Pulse Dial
Tone Dial
∗ ∗ ∗ ∗ 48
Report Format
0 = 3+1, 4+1 ADEMCO L/S STANDARD
1 = 3+1, 4+1 RADIONICS STANDARD
2 = 4+2 ADEMCO L/S STANDARD
3 = 4+2 RADIONICS STANDARD
5 = 10-digit ADEMCO CONTACT ID® REPORTING
6 = 4+2 ADEMCO EXPRESS
7 = 4-digit ADEMCO CONTACT ID® REPORTING
8 = 3+1, 4+1 ADEMCO L/S EXPANDED
9 = 3+1, 4+1 RADIONICS EXPANDED
– 3 –
|
|
[FFFF/FFFFFF] Enter 4 or 10 digits,
[FFFF/FFFFFF] See *43. To
USING WATS LINE
0
2
1
3
[77]
Primary Second
[1]
[0]
[1]
|
|
|
[1]