4.Adjustments
(2) Environmental Setup for AF Adjustments (Fig. B)
[1] Set the Siemens Star Chart 890
side of the conversion lens.
[2] Irradiate the Siemens Star Chart with a light source so
that the surface brightness of the Siemens Star Chart is
9.0 ~ 11.5Ev.
[3] Set the conversion lens concentric to the camera lens.
(3) Environmental Setup for Strobe Light Adjustment (Fig. C)
Because the strobe light is easily affected by external light,
keep the area around the gray chart extremely dark during
strobe light adjustment.
Set the gray chart 1000 mm from the camera's reference
surface (*2).
The gray chart must be Oxford Gray (No. 22) made by Su-
perior with a reflectance of 18
*2. The camera's reference surface for strobe light adjust-
ment is the front face of the strobe light emitter.
(4) Environmental Setup for Video Adjustments (Fig. D)
Video adjustments: NTSC/PAL
[Note]
Do not display the LCD monitor of the camera when the video
cable is set in "VIDEO OUT" of the camera.
Set the video cable only at the video adjustment.
(5) Environmental Setup for LCD Adjustments (Fig. E)
1) Set the LCD jig cover in the LCD adjustment jig.
2) Set for the LCD jig cover to cover the display part of
the LCD monitor.
*Fit the senser of LCD adjustment jig to the center of
the LCD monitor.
38
+
5 mm from the convex
+
0.7%.
FinePix S3000 Service Manual
<Fig. B> AF adjustment environment
<Fig. C> Strobe Light adjustment environment
<Fig. D> Video adjustment environment
<Fig. E> LCD adjustment environment