Elation Design Spot LED Manual page 40

Table of Contents

Advertisement

Design Spot LED™
05Er - Color-wheel error:
The color wheel is not located in the default position after start-up or after a reset command.
This message will appear after a fixture reset if the color wheel's magnetic-indexing circuit
malfunctions (sensor failed or magnet is missing) or there is a stepper motor failure
(defective motor or a defective motor IC drive on the main PCB).
06Er - Rotating gobo-wheel error:
The gobo-wheel is not located in the default position after start-up or after a reset command.
This message will appear after a fixture reset if the gobo wheel's magnetic-indexing circuit
malfunctions (sensor failed or magnet is missing) or there is a stepper motor failure
(defective motor or a defective motor IC drive on the main PCB).
07Er - Rotating gobo indexing error:
The gobo is not located in the default position after start-up or after a reset command. This
message will appear after a fixture reset if the gobo positioning magnetic-indexing circuit
malfunctions (sensor failed or magnet is missing) or there is a stepper motor failure
(defective motor or a defective motor IC drive on the main PCB).
08Er - Fix Gobo-wheel error
This message will appear after the reset of the fixture if the magnetic-indexing circuit
malfunctions (sensor failed or magnet missing) or the stepping-motor is defective (or its drive
circuit on the main PCB). The fix gobo wheel is not located in the default position after the
reset.
10Er - Focus-error
This message will appear after the reset of the fixture and if the magnetic indexingcircuit
malfunctions (sensor failed or magnet missing) or the stepping-motor isdefective (or its
driver circuit on the main PCB). The focus motor is not located in the defaultposition after the
reset.
13Er - Iris-error
This message will appear after the reset of the fixture and if the magnetic indexingcircuit
malfunctions (sensor failed or magnet missing) or the stepping-motor isdefective (or its
driver circuit on the main PCB). The Iris motor is not located in the default position after the
reset.