    13. DMX Channel Traits…...….…………………………………………………………….. 39 a. DMX Channel Values…………………………………………………………… 40 14. Error Codes………………………………………………………………………………. 42 15. Cleaning and Maintenance……………………………………………………………… 43 16. Photometric Data………………………………………………………………………….44 17. Dimensional Drawings………………………………………………….……………….. 45 18. Circuit Schematic………...………………………………………………………………. 46 19. Warranty……………………………………………………………………………………47 20. Technical Specifications…………………………………………...………….………… 49 ©Elation Professional, Los Angeles Ca. www.ElationLighting.com...
  • Page 4: General Information

    You may also visit us on the web at www.elationlighting.com for any comments or suggestions. For service related issue please contact Elation Professional Service Hours are Monday through Friday 8:00 a.m. to 5:00 p.m. Pacific Standard Time.
  • Page 5 Only handle the power cord by the plug. Never pull out the plug by tugging the wire portion of the cord. Please be aware that damages caused by manual modifications to the device are not subject to warranty. ©Elation Professional, Los Angeles Ca. www.ElationLighting.com...
  • Page 6: Safety Instructions

    9. Installation should only be performed by qualified and certified personal. Important Notice: Damages resulting from the disregard of safety and general user instructions found in this user manual are not subject to any warranty claims. ©Elation Professional, Los Angeles Ca. ™ is an extremely sophisticated piece ™...
  • Page 7: Features

    • 7 built-in programs accessed via DMX-controller or manually • Built-in DMX recorder - via the control board or external controller, up to 64 scenes can be saved and then can be run in Stand Alone or sound activated. ©Elation Professional, Los Angeles Ca. www.ElationLighting.com...
  • Page 8: General Guidelines

    Do not permit operation by persons not qualified for operating this type of theatrical fixture; most damages are the result of operations by nonprofessionals. Please use the original packaging to transport the fixture in for service. ©Elation Professional, Los Angeles Ca. www.ElationLighting.com...
  • Page 9: Fixture Overview

    8. LCD Menu Display 9. Carrying Handle 10. Cooling /Fan Assembly 11. 3-Pin DMX Output 12. 3-Pin DMX Input 13. Battery On/Off Button 14. 5-Pin DMX Output 15. Fuse Holder 16. 5-Pin DMX Input 17. Power Cord ©Elation Professional, Los Angeles Ca. www.ElationLighting.com...
  • Page 10 To prevent the fixture from overheating, never block the back of the head during normal operation. 11. 3-Pin DMX Output Jack – This jack is used to send an incoming DMX signal to the next ©Elation Professional, Los Angeles Ca. www.ElationLighting.com...
  • Page 11 16. 5-PIN DMX Input Jack – This jack accepts an incoming DMX signal via a male, 5-pin XLR jack. 17. Power Cord – Plug into an appropriate power outlet to provide main power to the fixture. ©Elation Professional, Los Angeles Ca. www.ElationLighting.com...
  • Page 12: Mounting And Installation

    Refer to regulations BGV C1 (formerly VBG 70) and DIN VDE0711-217 for proper installation in Europe To ensure proper installation, only qualified staff should attempt installation. ©Elation Professional, Los Angeles Ca. ™ is fully operational in two different mounting positions, hanging...
  • Page 13: Mounting Points

    Improper installation can result in bodily injury. CAUTION! Be sure a qualified electrician performs all electrical connections. Be sure to complete all rigging and installation procedures before connecting the main power cord to the appropriate wall outlet. ©Elation Professional, Los Angeles Ca. www.ElationLighting.com...
  • Page 14: Securing

    The fixture provides a built-in rigging point for a safety cable on the hanging bracket as illustrated above. Be sure to only use the designated rigging point for the safety cable and never secure a safety cable to a carrying handle. ©Elation Professional, Los Angeles Ca. www.ElationLighting.com...
  • Page 15: Understanding Dmx

    120 ohms; this cable is designed for DMX transmission and may be purchased from your Elation dealer or at most professional lighting retailers. Your cables should be made with a male and female XLR connector on either end of the cable. Also, remember that a DMX line ©Elation Professional, Los Angeles Ca. www.ElationLighting.com...
  • Page 16 Always be sure daisy chain your in and out data connections, never split or “Y” your DMX connections unless you are using an approved DMX splitter such as the Elation Opto Branch 4™ or DMX Branch/4™. ©Elation Professional, Los Angeles Ca. www.ElationLighting.com...
  • Page 17 All fixtures should be given a DMX starting address when using a DMX controller, so the correct fixture responds to the correct control signal. This digital starting address is the channel number from which the fixture starts to “listen” to the digital control information sent ©Elation Professional, Los Angeles Ca. www.ElationLighting.com...
  • Page 18 The DMX controller is switched off or defective. The DMX cable or connector is defective. A DMX terminator has been inserted into the last fixture in your DMX chain. ©Elation Professional, Los Angeles Ca. ™ will automatically detect whether a DMX...
  • Page 19: Fixture Menu

    MENU button. Default settings shaded. Set Dmx Address Value Display Set To Slave Auto Program Music Control ©Elation Professional, Los Angeles Ca. ™ A001~AXXX PAN…… Slave1,Slave2,Slave3 Master / Alone Master / Alone comes with an easy to navigate...
  • Page 20 Test Channel PAN …… Manual Control Calibrate Values --Password-- User Mode XXXXXX(Band) User Mode A User Mode B User Mode C Edit User Mode ©Elation Professional, Los Angeles Ca. XXXX(Hours) XXXX(Hours) XXXX(Hours) Password=XXX ON/OFF XXX!/" ON/OFF Close/Hold/Auto/Music ON/OFF ON/OFF ON/OFF...
  • Page 21: Dmx Addressing

    With this function, you can define the device as slave for operation in Master/Slave mode. Each slave setting will have a different function for a dynamic lightshow without a controller. ©Elation Professional, Los Angeles Ca. Program 1 ~ 10 Program 1 Program 1 ~ 10 Program 2...
  • Page 22 Last Run Hours This function tracks the number of hours the fixture was operating on it’s previous cycle. Where “XXXX” represents the number of hours. This counter is automatically reset after every power down. ©Elation Professional, Los Angeles Ca. www.ElationLighting.com...
  • Page 23 • Press the Mode/Esc-button to return to the main menu. 8.3 Personality: 8.3.1 Status setting Address via DMX - This function allows the DMX address to remotely be adjusted from a DMX console. This setting requires special settings for both the controller and ©Elation Professional, Los Angeles Ca. www.ElationLighting.com...
  • Page 24 DMX channels needed to operate the unit to 13. Pan Degree – This function changes the maximum Pan resolution from either 540˚ or 630˚. The default function is 540˚. 630˚ operation allows for greater coverage, but slower pan movement. ©Elation Professional, Los Angeles Ca. www.ElationLighting.com...
  • Page 25 This setting should only be used in extreme cases of higher than normal temperatures. Using the fans in “HIGH” mode will decrease fan life over time. Low is ©Elation Professional, Los Angeles Ca. ™ ™...
  • Page 26 All settings will be set back to the default values (shaded). Any edited scenes will be lost. 8.5 Reset Functions: The reset function returns a motor to the “Home” position. There are several reset functions available on this fixture. The list below details the functionality of ©Elation Professional, Los Angeles Ca. www.ElationLighting.com...
  • Page 27 A total of three user modes may be configured: User Mode A, User Mode B, and User Mode C: ©Elation Professional, Los Angeles Ca. www.ElationLighting.com...
  • Page 28 Pre-programmed scenes can be transmitted to the fixture via any DMX compliant controller. This function allows those scenes to be stored in to the fixture’s built-in memory and then subsequently used to create the user-defined programs. ©Elation Professional, Los Angeles Ca. ™ features an integrated DMX www.ElationLighting.com...
  • Page 29: Dmx Addressing

    4. “Address via DMX” is the function that turn the RDMX function on and off. Press ENTER and be sure the function is turned on. 5. Press the UP button to display “ON” to activate this function, or “OFF” to deactivate this function. ©Elation Professional, Los Angeles Ca. www.ElationLighting.com...
  • Page 30 420, set channel 1 to a value of “7,” channel 2 to "8" and channel 3 to "164" (256+164=420). 4. Wait for approximately 20 seconds for the unit to complete the address reset function. ©Elation Professional, Los Angeles Ca. www.ElationLighting.com...
  • Page 31: Operation

    “Auto Program” submenu select “Alone” " For functionality that chases to sound: Access the “Function” menu and select the “Music Control” function, this will give you access to the “Music ©Elation Professional, Los Angeles Ca. Show Designer 2. ® www.ElationLighting.com...
  • Page 32 " Be sure to use a terminator on the last fixture, especially for longer cable runs (more than a 100 feet). " For help operating in DMX mode be sure to consult the manual that was included with your DMX controller. ©Elation Professional, Los Angeles Ca. ™ Show Designer 2 or Elation ®...
  • Page 33: Working With Built-In Programs

    Tapping the “ENTER” button will instantly allow you to change the values of the selected function in real time. The values can be adjusted from 0~250. Once you achieved your desired value tap the “ENTER” button once again to automatically ©Elation Professional, Los Angeles Ca. www.ElationLighting.com...
  • Page 34 The control will store a maximum of 10 programs. A program can store one or a maximum of 64 scenes. Keep in mind that a scene can only be access when it is stored inside one of the 10 available programs. Follow the procedure below to build an internal program: ©Elation Professional, Los Angeles Ca. www.ElationLighting.com...
  • Page 35 See section 10.1 “Stand-Alone Operation” on page 32 for proper set-up instructions. The 3 Slave groups run the Auto Program in certain time segments, as shown in the following diagram: ©Elation Professional, Los Angeles Ca. www.ElationLighting.com...
  • Page 36: Built-In Wireless Receiver

    The red/green LED indicators on the transmitter and the fixture should then begin to flash rapidly for about 5~ 10 seconds while the two system pair c) Once the fixture is paired with the transmitter (T1), the WDMX status indicators ©Elation Professional, Los Angeles Ca. WARNING! to the controller.
  • Page 37 2) Slow flashing Red/Green: Paired with a transmitter. Transmitter is not receiving a DMX signal from a controller. 3) Solid Green: Paired with a transmitter and receiving DMX data. 4) Solid Red: Not paired with a transmitter (free) ©Elation Professional, Los Angeles Ca. www.ElationLighting.com...
  • Page 38: Dmx Channel Traits

    CHANNEL 10: Dimmer (Intensity) Control CHANNEL 11: Color Macros (CMY and Color Wheels) CHANNEL 12: Speed Control (Pan/Tilt movement, blackout selection) CHANNEL 13: Special (program control + lamp on, motor reset, lamp switch off) ©Elation Professional, Los Angeles Ca. www.ElationLighting.com...
  • Page 39 Random Strobe Effect - slow to fast 224-255 Shutter Open – LEDs On Channel 10 - Dimmer (intensity): 0-255 Intensity 0 to 100% Channel 11 - Rainbow: No function 8-231 Rainbow colors 232-255 Cross fading colors from slow to fast ©Elation Professional, Los Angeles Ca. www.ElationLighting.com...
  • Page 40 Internal program 4 (secne25~32 of EEPROM) 180-199 Internal program 5 (secne33~40 of EEPROM) 200-219 Internal program 6 (secne41~48 of EEPROM) 220-239 Internal program 7 (secne49~56 of EEPROM) 240-255 Music Control (scene of Program 1) ©Elation Professional, Los Angeles Ca. www.ElationLighting.com...
  • Page 41: Error Codes

    (sensor failed or magnet is missing) or there is a motor failure (defective motor or a defective motor IC drive on the main PCB). This error may also be displayed if the head was blocked during a reset function. ©Elation Professional, Los Angeles Ca. www.ElationLighting.com...
  • Page 42: Cleaning And Maintenance

    There are no user serviceable parts inside this fixture with the exception of the lamp. Please refer all other service related issues to an authorized Elation service technician. Should you decide to service the fixture yourself please order genuine Elation parts directly from Elation. ©Elation Professional, Los Angeles Ca. www.ElationLighting.com...
  • Page 43: Photometric Data

    Design Wash LED Pro™ 16. PHOTOMETRIC DATA: ©Elation Professional, Los Angeles Ca. www.ElationLighting.com...
  • Page 44: Dimensional Drawings

    Design Wash LED Pro™ DIMENSIONAL DRAWINGS: ©Elation Professional, Los Angeles Ca. www.ElationLighting.com...
  • Page 45: Circuit Schematic

    Design Wash LED Pro™ 18. CIRCUIT SCHEMATICS ©Elation Professional, Los Angeles Ca. www.ElationLighting.com...
  • Page 46: Warranty

    B. For warranty service, send the product only to the Elation Professional shipping charges must be pre-paid. If the requested repairs or service (including parts replacement) are within the terms of this warranty, Elation Professional shipping charges only to a designated point within the United States.
  • Page 47 ® liable for any loss or damage, direct or consequential, arising out of the use of, or inability to use, this product. G. This warranty is the only written warranty applicable to Elation Professional Products ® and supersedes all prior warranties and written descriptions of warranty terms and conditions heretofore published.
  • Page 48: Technical Specifications

    Weight (net) Please Note: Specifications and improvements in the design of this unit and this manual are subject to change without any prior written notice. ©Elation Professional, Los Angeles Ca. 100~240v 50/60Hz Internal Voltage Taps 120V = 5A/250V, GMA (5x20mm fine-wire fuse) 220V = 3.15A/250V, GMA (5x20mm fine-wire fuse)
  • Page 49 Design Wash LED Pro™ ©Elation Professional, Los Angeles Ca. www.ElationLighting.com...
  • Page 50 Design Wash LED Pro™ ©Elation Professional, Los Angeles Ca. www.ElationLighting.com...
  • Page 51 Design Wash LED Pro™ ©Elation Professional, Los Angeles Ca. www.ElationLighting.com...
  • Page 52 Elation Professional ® 6122 S. Eastern Ave. Los Angeles, CA. 90040 323-582-3322 / 323-832-9142 fax www.ElationLighting.com / Info@ElationLighitng.com Version 1.0...

This manual is also suitable for:

Design wash led pro

Table of Contents