WARNING! READ AND UNDERSTAND ALL SAFETY PRECAUTIONS
IN THIS MANUAL BEFORE OPERATING. FAILURE TO COMPLY WITH
INSTRUCTIONS IN THIS MANUAL COULD RESULT IN PERSONAL
INJURY, PROPERTY DAMAGE, AND/ OR VOIDING OF YOUR WARRANTY.
GENTRON/UPC PRODUCTS WILL NOT BE LIABLE FOR ANY
DAMAGE BECAUSE OF FAILURE TO FOLLOW THESE INSTRUCTIONS.
Page
3
5
6
15
16
17
22
23
29
31
32
3
3
2

Advertisement

Table of Contents
loading

Summary of Contents for GENTRON 10000W

  • Page 1: Table Of Contents

    IN THIS MANUAL BEFORE OPERATING. FAILURE TO COMPLY WITH INSTRUCTIONS IN THIS MANUAL COULD RESULT IN PERSONAL INJURY, PROPERTY DAMAGE, AND/ OR VOIDING OF YOUR WARRANTY. GENTRON/UPC PRODUCTS WILL NOT BE LIABLE FOR ANY DAMAGE BECAUSE OF FAILURE TO FOLLOW THESE INSTRUCTIONS.
  • Page 2 Gentron/UPC warrants to the original purchaser who uses the product in a consumer application Merchandise sold by Gentron/UPC which has been manufactured by and identified as the product of another (personal, residential or household usage) that all products covered under this warranty are free from company, such as gasoline engines.
  • Page 3 Owner’s Manual Safety Guidelines - Definitions This manual contains important information that you need to know and understand in order to protect YOUR SAFETY and to PREVENT EQUIPMENT PROBLEMS. The following symbols help you recognize this information. Please read the manual and pay attention to these sections. Save These Important Safety Instructions! Read and understand all of these safety instructions.
  • Page 4 CAUTION: ATTEMPTING TO POWER SENSITIVE ELECTRONIC EQUIPMENT WITHOUT THE USE OF AN APPROVED LINE CONDITIONER MAY CAUSE DAMAGE TO THE EQUIPMENT. GENTRON/UPC IS NOT RESPONSIBLE FOR ANY DIRECT OR INDIRECT DAMAGE CAUSED BY FAILURE TO USE AN APPROVED LINE CONDITIONER.
  • Page 5 Owner’s Manual General Precautions (cont’d) Electrical Safety (cont’d) • All connections and conduits from the generator to the load must only be installed by trained and licensed electricians, and in compliance with all relevant local, state, and federal electrical codes and standards, and other regulations where applicable. •...
  • Page 6 Owner’s Manual 10000W Generator General Precautions (contíd) General Precautions (cont’d) Installation (contíd) Servicing Maintain labels and name plates on the generator and engine. These carry important information. If the generator is installed outdoors, it must be weatherproofed and should be soundproofed. It If unreadable or missing, contact our service center toll free at 800-894-1179 immediately for a should not be run outdoors without protection to the generator and wiring conduit.
  • Page 7 Owner’s Manual General Precautions (cont’d) Mechanical (cont’d) Do not operate the generator with safety guards removed. While the generator is running, do not attempt to reach around the safety guard for maintenance or any other reason. Keep hands, arms, long hair, loose clothing, and jewelry away from moving parts. Be aware that when engine parts are moving fast they cannot be seen clearly.
  • Page 8: Battery

    10000W Generator Owner’s Manual Assembly Battery Unpacking To start generator with electric start you will need a battery (not included). You can use a 12v lawn 1. Remove the generator and loose parts box from the carton. tractor battery with the following specifications: The dimensions are Wx7.5” Dx5” Hx7” (including 2.
  • Page 9: Operation

    Owner’s Manual Operation Control Panel Choke lever Handle Battery Oil plug Air filter Recoil Start NOTE: THE PARTS LISTED ABOVE ARE HELPFUL FOR LOCATING THE CONTROLS MENTIONED BELOW. CAUTION: PRIOR TO FIRST USING THE GENERATOR, THE ENGINE MUST BE FILLED WITH OIL OF A HIGH QUALITY SAE 10W-30 GRADE ENGINE OIL. TO DO SO, UNSCREW AND REMOVE THE ENGINE’S OIL DIPSTICK LOCATED AT THE BOTTOM OF THE ENGINE CRANKCASE.
  • Page 10 CAUTION: ATTEMPTING TO POWER SENSITIVE ELECTRONIC EQUIPMENT WITHOUT THE USE OF AN APPROVED LINE CONDITIONER MAY CAUSE DAMAGE TO THE EQUIPMENT. GENTRON/UPC PRODUCTS ARE NOT RESPONSIBLE FOR ANY DIRECT OR INDIRECT DAMAGE CAUSED BY FAILURE TO USE AN APPROVED LINE CONDITIONER.
  • Page 11: Spark Plug Service

    10000W Generator Owner’s Manual Operation (cont’d) Spark Plug Service Powering 12 Volt DC tools and Equipment: 1. Prior to powering tools and equipment, make sure the generator’s rated voltage, and amperage In order to service the spark plug, you will need a spark plug wrench (commercially available).
  • Page 12: Inspection, Cleaning, Maintenance And Storage

    Owner’s Manual Inspection, Cleaning, and Maintenance WARNING! ALWAYS MAKE SURE THE ENGINE POWER SWITCH (2) IS IN ITS “OFF” POSITION. DISCONNECT THE SPARK PLUG WIRE FROM THE ENGINE. AND ALLOW SUFFICIENT TIME FOR THE ENGINE AND GENERATOR TO COMPLETELY COOL BEFORE PERFORMING ANY INSPECTIONS, MAINTENANCE, OR CLEANING.
  • Page 13 Owner’s Manual Maintenance Guide Periodic maintenance and adjustment is necessary to keep the generator in good operating condition. WARNING! Exhaust gas contains poisonous carbon monoxide. Shut off the engine before performing any maintenance. If the engine must be run, make sure the areas is well ventilated. •...
  • Page 14 Owner’s Manual...
  • Page 15: Installation

    Owner’s Manual Installation NOTE: PRIOR TO POWERING TOOLS AND EQUIPMENT MAKE SURE THE GENERATOR’S RATED VOLTAGE, WATTAGE AND AMPERAGE CAPACITY IS ADEQUATE TO SUPPLY ALL ELECTRICAL LOADS THAT THE UNIT WILL POWER. IF POWERING EXCEEDS THE GENERATOR’S CAPACITY, IT MAY BE NECESSARY TO GROUP ONE OR MORE OF THE TOOLS AND/OR EQUIPMENT FOR CONNECTION TO A SEPARATE GENERATOR.
  • Page 16: Compliance

    10000W Generator Compliance You should get a certificate of EPA while you purchased this product. Model GG10020 120V/240 AC @ 66.7/33.3A 60Hz 8,000 WATTS 10,000 WATTS (4) 120V AC outlets, (1) 120V AC twist-lock (1) 120/240V AC twist-lock outlet 11 hours(approx.) @ 1/2 load...
  • Page 17: Parts Listing

    10000W Generator Cylinder head system assy. PARTS LISTING APA Part No. Description ( 1 × 1...
  • Page 18 10000W Generator 10000W Generator Crankcase cover system assy. Cylinder barrel APA Part No. APA Part No. Description Description APG3090-B-01-JD FLANGE BOLT APG3090-C-01-JD DUCT COVER APG3090-B-02-JD OIL LEVEL SWITCH ASSY APG3090-C-02-JD FLANGE BOLT (M8 X 35) APG3090-C-03-JD OIL SCALE APG3090-B-03-JD O-RING...
  • Page 19 10000W Generator 10000W Generator Crankshaft system assy. Piston and connecting rod system assy. Description Description APA Part No. APA Part No. APG3090-D-01-JD CRANKSHAFT COMP APG3090-E-01-JD COMPRESSION RING A APG3090-E-02-JD COMPRESSION RING B APG3090-D-02-JD BALANCER WEIGHT APG3090-E-03-JD OIL RING A APG3090-E-04-JD...
  • Page 20 10000W Generator 10000W Generator Recoil starter system assy. Recoil starter system assy. Description Description APA Part No. APA Part No. APGG1000-G-01-JD RECOIL STARTER ASSY APG3090-F-01-JD PIVOT ADJUSTING NUT APG3090-G-02-JD SETTING SCREW APG3090-F-02-JD ROCKER ARM PIVOT APG3090-F-03-JD ROCKER ARM APG3090-G-03-JD SPRING RETAINER...
  • Page 21 10000W Generator 10000W Generator Fan cover system assy. Carburetor system assy. Description Description APA Part No. APA Part No. APG3090-H-01-JD SHROUD APG3090-I-01-JD TUBE CLIP APG3090-H-02-JD FLANGE BOLT (M6 X 14) APG3090-I-02-JD TUBE A APGG10000-H-03-JD FAN COVER COMP APG3090-I-03-JD TUBE B...
  • Page 22 10000W Generator 10000W Generator Flywheel system Assy. Ignition System Assy. Description Description APA Part No. APA Part No. APG3090-J-01-JD FLYWHEEL APG3090-K-01-JD SPARK PLUG CAP ASSY APG3090-K-02-JD IGNITION COIL ASSY APG3090-J-02-JD SPECIAL WOODRUFF KEY APG3090-J-03-JD COOLING FAN APG3090-K-03-JD STOP SWITCH CORD...
  • Page 23 10000W Generator 10000W Generator Starter motor System assy. Control System Assy. APA Part No. Description Description APA Part No. APG3090-01-JD STARTER MOTOR APG3090-M-01-JD CONTROL ASSY APG3090-02-JD SOLENOID APG3090-M-02-JD CONTROL BASE COMP APG3090-03-JD FLANGE BOLT (M8×35) APG3090-M-03-JD CONTROL ADJUSTING APG3090-M-04-JD PAN SCREW (M5 X 34)
  • Page 24: Air Cleaner

    10000W Generator 10000W Generator Air cleaner Muffler System Assy. Description APA Part No. Description APA Part No. APG3090-O-01-JD AIR CLEANER COVER COMP APG3090-N-01-JD FLANGE BOLT (M8 X 16) APG3090-O-02-JD AIR CLEANER ELEMENT APG3090-N-02-JD FLANGE BOLT (M6 X 12) APG3090-N-03-JD MUFFLER STAY COMP.
  • Page 25: Control Box Assy

    10000W Generator 10000W Generator Fuel tank system assy. Control box assy. Description APA Part No. APGG10000-P-01-JD FUEL FILLER CAP COMP APGG10000-P-02-JD FUEL FILTER APGG10000-P-03-JD FUEL TANK COMP Description APA Part No. APGG10000-P-04-JD FUEL METER ASSY APGG10000-Q-01-JD CONTROL PANEL COMP APGG10000-P-05-JD...
  • Page 26 10000W Generator 10000W Generator Frame Comp assy. Generator Description APA Part No. APG3090-S-01-JD STATOR COVER APG3090-S-02-JD STATOR ASSY Description APG3090-S-03-JD COOLING FAN APA Part No. APG3090-S-04-JD BRUSH ASSY APGG10000-R-01-JD BOLT APGG10000-R-02-JD REAR COVER APG3090-S-05-JD TAPPING SCREW APG3090-S-06-JD GENERATOR STAY APGG10000-R-03-JD...
  • Page 27 10000W Generator 10000W Generator Generator Wheel and hand assy. APA Part No. Description APG3090-S-16-JD HEX.BOLT (M5 X 20) APG3090-S-17-JD VOLT CHANGE TERMINAL BR-AC-W APG3090-S-18-JD PLAIN WASHER (5mm) APG3090-S-19-JD HEX. NUT (M5) APG3090-S-20-JD SPRING WASHER (5mm) 10 11 Description APA Part No.
  • Page 28 Distributed by: Universal Product Concepts Inc. www.gentronusa.com...