GENTRON G2000D Owner's Manual

2000w digital generator

Advertisement

Quick Links

DANGER
Carbon Monoxide
Using
a generator
indoors
WiLL
KiLL
YOU
iN MINUTES.
Carbon
Monoxide
Generator
exhaust contains high levels of carbon monoxide
(CO), a poisonous
gas you cannot see or smell• If you can smell the generator
exhaust, you are
breathing
CO• But even If you cannot smell the exhaust, you could be breathing
CO.
• NEVER use a generator
inside homes, garages,
crawlspaces,
or other partly
enclosed areas. Deadly levels of carbon monoxide can build up in these areas.
Using a fan or opening windows
and doors does NOT supply enough fresh air.
• ONLY use a generator
outdoors
and far away from open windows,
doors, and
vents• These openings
can pull in generator
exhaust.
Even when you use a generator
correctly,
CO may leak into the home. ALWAYS
use a battery-powered
or battery-backup
CO alarm in the home.
If you start to feel sick, dizzy, or weak after the generator
has been running,
move to fresh air RIGHT AWAY. See a doctor. You could have carbon
monoxide
poisoning.
BEN
I RON
Owner's
Manual
2000W
DIGITAL
G
N
RATOR
Pleasereadsnd savetheseinstructions.
www.
GentronUSA.
corn

Advertisement

Table of Contents
loading

Summary of Contents for GENTRON G2000D

  • Page 1 I RON DANGER Carbon Monoxide Using a generator indoors WiLL KiLL iN MINUTES. Owner's Manual Carbon Monoxide 2000W DIGITAL Generator exhaust contains high levels of carbon monoxide (CO), a poisonous gas you cannot see or smell• If you can smell the generator exhaust, you are RATOR breathing...
  • Page 2 • Thank you for purchasing a generator. • This manual covers operation and maintenance of the generator. • Reserves the right to make changes at anytime without notice and without taking any obligation. This publication can't be reproduced without written permission.
  • Page 3 • Always make a pre-operation inspection (page 8) before you start the engine. • Place the generator at least 1 m (3 ft) away from buildings or other equipment during operation. • Operate the genernator on a level surfuce. If the generator is tilted, fuel spillage may result.
  • Page 4: Control Panel

    CONTROL PANEL •CHOKE LEVER • FUEL CAP LEVER • OILALERT INDICATOR LIGHT • OUTPUT INDICATOR LIGHT • OVERLOAD INDICATOR •FUELCAP • DC RECEPTACLE • DC CIRCULT PROTECTOR ' CONTROL PANEL • FUEL COCK • ENGINE SWITCH "LEFT SIDE • Ground MAINTENANCE •...
  • Page 5 @ Check the fuel level. Unleaded or Iowleaded is preferred to minimize com-bustion chamber deposits. O Check oil level. If the fuel level is low, refuel the fuel tank. Loosen the cover screw and remove the left side maintenance cover. Never use an oil/gasoline misture...
  • Page 6: Maintenance Cover

    ® Check the air cleaner. Before starting the engine, disconnect the load from the DC terminals. Check the air cleaner element to be sure it is clean and in good condition. Loosen the cover screw and remove the left side maintenance cover.
  • Page 7: Starter Grip

    @ Pull the starter grip until resistance is felt, then pull the starter grip briskly toward the arrow as shown below. CAUTION: Do not allow the starter grip to snap back. To prevent electrical shock from faulty appliances, the generator should be grounded.
  • Page 8 NOTE: • An overloaded DC circuit will trip the DC circuit protector (push button comes out). The DC circuit protector will trip when it's overloaded. If this happens, wait a few minutes before pushing in the circuit protector before resuming operation. INDICATOR LIGHT •AC RECEPTACLE...
  • Page 9: Oil Alert Indicator

    y!'_ _'Avl_,_ _1 I_[_ • The battey gives off explosive gases; keep sparks, flames and cigarettes away. Provide adequate ventilation when charging. To stop the engine in an emergency, turn the engine switch to the STOP position. • The battey contains sulfuric acid (electrolyte). If it gets into your skin or eyes it will IN NORMAL CONDITION:...
  • Page 10 ®Turn the fuel c ap lever c ounterclockwise tothe"OFF" posiltion. CAUTION: Besure thefuel c aplever a nd theengine s witch are"OFF" when stopping, transporting and/or s toring thegenerator. The purpose of maintenance and adjustment schedule is to keep the generator in the best operating condition.
  • Page 11: Engine Oil Capacity

    @CHANGING Drain t heoil w hile the engine isstill w arm. CAUTION: Make sure to turn the engine switch and the fuel cap lever OFF be- fore draining• • Loosen the cover screw and remove the left side maintenance cover. •...
  • Page 12 ® SPARK PLUG SERVICE RECOMMENDED SPARK PLUG: CR5H88 (NGK) U16FSR - UB (DENSO) To ensure proper engine operation, the spark plug must be properly gapped •AIR FILTER ELEMENT and free of deposits. Remove the spark plug maintenance cover. FILTER GAP "SPARK PLUG MAINTENANCE...
  • Page 13 • Visually inspect the spark plug. Discard it if the insulator is cracked Clean the spark plug with a wire brush if it can be reused. • Measure the plug gap with a feeler gauge. The gap should be 0.6-0.7mm,correct as necessary by carefully bending the...
  • Page 14 When the engine will not start: Be sure there is no spilled fuel around the spark plug. Is there fuel in the tank? Is the engine switch on ? _! YES I.° Refill the fuel tank. If the engine still does I Turn the engine switch not start, take the generator...
  • Page 15 Appliance does not operate: output light Engine lls the indicator Engine type 14_stioke' overhead valve, single Cylinder Is the overload indicator light ON? Bore x stroke ¢_54x 38nm Compression ratio 10:1 Engine speed 4000"-_ 5000 r.p.m Check the electrical appliance equipment for any defects.
  • Page 16: This Warranty Does Not Cover

    Owner's M anual(s) supplied withtheproduct, i mproper m aintenance, theuseofaccessories or Gentron® willrepair o r replace, at Gentron's soleoption, p roducts or components attachments notrecommended byGentron®, or unauthorized repair o r alterations.

This manual is also suitable for:

Pro2 g2000d

Table of Contents