Please read and save this user's manual. Read carefully before attempting to assemble, install, operate or
maintain the product described. Protect yourself and others by observing all safety information. Failure to
comply with the user' manual could result in personal injure and/or property damage! Retain the user's
manual for future reference.
Owner's Manual

Advertisement

Table of Contents
loading

Summary of Contents for GENTRON 950W Series

  • Page 1 GENTRON 950W Series Gasoline Generators Please read and save this user’s manual. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with the user’ manual could result in personal injure and/or property damage! Retain the user’s manual for future reference.
  • Page 2: Table Of Contents

    CONTENTS ………………………………………2 1. SAFETY INFORMATION ………………………………………2 2. CONTROL FUNCTION …………………………………3 3. PRE-OPERATION CHECK …………………………………………………4 4. OPERATION ………………………………5 5. PERIODIC MAINTENANCE ……………………………………………………6 6. STORAGE ……………………………………… 7 SPECIFICATIONS ……………………………8 8. GENERATOR SCHEME DIAGRAM...
  • Page 3: Safety Information

    ! WARNING PLEASE READ AND UNDERSTAND THIS MANUAL COMPLETELY BEFORE OPERATING THE MATCHINE. Ⅰ SAFETY INFORMATION EXHAUST FUMES ARE POISONOUS Never operate the engine in a closed area or it may cause unconsciousness and death within a short time. Operate the engine in a well ventilated area. FUEL IS HIGHLY FLAMMABLE AND POISONOUS Always turn off the engine when refueling.
  • Page 4: Control Function

    Ⅱ CONTROL FUNCTION ENGINE SWITCH The engine switch controls the ignition system. ① “ON” Ignition circuit is switched on. The engine can be started. ② “OFF” Ignition circuit is switched off. The engine will not run. AC BREAKER (N.F.B) The AC breaker turns off automatically when the load exceeds the generator rated output.Press the reset button to reset the protector.
  • Page 5 ! WARNING Fuel is highly flammable. Check “ SAFETY INFORMATION” carefully before refueling. Do not fill above the top of the fuel fill or it may overflow when the fuel heats up later and expands.Add fuel until level is approximately 1 inch from top of fuel fill. After refueling, make sure the tank cap is tightened securely.
  • Page 6 CAUTION: Be sure the electric apparatus is turned off before plugging in. Be sure the total load is within generator rated output. Be sure the socket load current is within socket rated current. Ⅰ Wind the power lead 2 or 3 turns around frame. Ⅱ...
  • Page 7: Operation

    MAINTENANCE CHART Regular maintenance is most important for the best performance and safe operation. Pre- Initial Every Every 6 Every Operati months month months months Item remarks check 100Hr (daily) 300Hr Spark Plug Check condition adjust gap and clean. Replace if necessary.
  • Page 8: Spark Plug Inspection

    CAUTION: Do not wring out the element. This could cause it to tear. Be sure the element sealing surface matches the air filter so there is no air leak. The engine should never run without the element sealing, excessive piston and or cylinder wear may result. !...
  • Page 9: Storage

    Ⅵ Store the generator in a dry, well-ventilated place, with the cover place over it. Ⅶ The generator must remain in a horizontel position. Ⅶ SPECIFICATION DIMENSIONS: DIMENSIONS GENTRON 950W Overall Length (mm) Overall Wide (mm) Overall Height (mm) Dry Weight (kg) GENERATOR:...
  • Page 10: Specifications

    DC Rated voltage(V) DC Rated current(A) ENGINE: ENGINE LY1E45FD single cylinder,2-stroke, Type forced air cooling Bore×Stroke (mm) 45×40 Displacement(mL) Compression Ratio 7.4:1 Max. output(Kw/rpm) 1.47/4000 Lubricate Mixed oil brume lubrication Fuel No 90# gasoline Oil No Purpose oil for 2-stroke Starting Manual starting Output Mode...
  • Page 11 Stator Auxiliary Winding...