Problem
Shortening will not heat
Shortening heating slowly
4-7
Cause
HEATING OF SHORTENING SECTION
Blown fuse or tripped circuit
at supply box
breaker
• Faulty cord and plug
• Faulty PC board
• Faulty or tripped high limit;
"E10"
• Drain valve open;
• Possible faulty probe;
• Possible faulty contactor
• Faulty POWER switch
• Faulty drain switch;
• Low or improper amps
Model OFE/OFG-321,322,323,324
• Reset breaker or replace fuse
• Check cord and plug and
check power at wall
receptacle
• Have control panel checked
• Reset high limit per
Operating Components
Section; if high limit doesn't
reset, have it checked
"E15"
• Close drain valve
"E6"
• Have temperature probe
checked
See Diagnostic Modes D 4;
if
"CHECK COILS,
CONTACTORS AND
WIRING"
have contactors and wiring
checked
• See Information Mode 11
"E15"
and check to see if
the input code is present; if
not, have fryer checked by a
certified service technician
• See Infomation Mode 17
for present amperage; or see
Information Modes 4, 5, 6,
7, 8, 9, and 10 for more
information on this problem.
Diagnostic Mode D 4 gives
present day's heating
performance
Correction
shows on display;
503