Local Codes - Superior Gas Log Installation And Operation Instructions Manual

Vented decorative natural gas log
Table of Contents

Advertisement

CHECK GAS TYPE
Use only natural gas. If your gas supply is not
natural gas, you must install ON/OFF Safety
Valve/Pilot Kit (see Accessories, page 24).
Call dealer where you bought log set.
If the fireplace does not have a gas supply
shutoff valve, one must be installed.
VENTING SPECIFICATIONS FOR
INSTALLATION
The fireplace chimney flue and vent must be
drafting properly. To check the vent for proper
drafting: Light a tightly rolled newspaper on
one end and place it at the inside front edge
of the fireplace. Observe the smoke and be
sure the vent is properly drawing it up the
chimney. If the smoke spills out into the room,
extinguish the flame and remove any obstruc-
tion until proper venting is achieved.
The chimney flue must remain open a mini-
mum of 3" at all times during the operation
of this log set.
For Massachusetts Residents Only
Installation of this vented gas log set in the
Commonwealth of Massachusetts requires
the damper be permanently removed or
welded in the fully open position.
INSTALLING DAMPER CLAMP
Secure the damper stop clamp provided to
the leading edge of the damper as shown in
Figure 3. If for any reason this clamp doesn't
work on your fireplace, another suitable clamp
or permanent stop must be installed, or the
damper blade must be cut or removed.
Damper
Clamp
Damper
Masonry Fireplace
Figure 3 - Attaching Damper Clamp
126904-01A
INSTALLATION
Continued
Damper
Damper
Clamp
Manufactured
Fireplace
www.SuperiorFireplaces.US.com
CONNECTING TO GAS SUPPLY
WARNING: A qualified ser-
vice person must connect log
set to gas supply. Follow all

local codes.

Installation Items Needed
Before installing log set, make sure you have
the items listed below.
• piping (check local codes)
• sealant (resistant to Propane/LP gas)
• equipment shutoff valve
• test gauge connection
• adjustable (crescent) wrench or pliers
• sediment trap
• tee joint
• pipe wrench
CAUTION: Use only new,
black iron or steel pipe. Inter-
nally-tinned copper tubing may
be used in certain areas. Check
your local codes. Use pipe of
1/2" diameter or greater to allow
proper gas volume to log set. If
pipe is too small, undue loss of
volume will occur.
Installation must include a equipment shutoff
valve, union, and plugged 1/8" NPT tap. Lo-
cate NPT tap within reach for test gauge hook
up. NPT tap must be upstream from log set
(see Figure 4, page 8).
IMPORTANT: Install equipment shutoff valve
in an accessible location. The equipment
shutoff valve is for turning on or shutting off
the gas to the appliance.
Apply pipe joint sealant lightly to male NPT
threads. This will prevent excess sealant from
going into pipe. Excess sealant in pipe could
result in a clogged burner injector.
WARNING: Use pipe joint
sealant that is resistant to liquid
petroleum (LP) gas.
7