Samsung S1050 Service Manual page 84

Hide thumbs Also See for S1050:
Table of Contents

Advertisement

Ⅲ. ADJUSTMENT
7) SHUTTER CLOSE TIME ADJ
Adjust the Closing timing of machanical shutter.
As the shutter closing time is different depend on the camera set the reduce the differences by adjusting the
camera.
<How to act>
① Adjust the Shutter closing tiime after checking the number of maxium setting up adjustment.
* The standard luminance of Light box is 13 LV.
* The standard colour temperature of Light box is 3300K.
② Do the adjustment by referencing standard luminanace.
- The Line delay and Sub delay is adjusted to find the proper value at standard luminance.
- First Line delay and Sube delay value is assigned at the script.
③ If the result of Line delay is located between standard minium and maxium value, OK and if not, NG.
④ Write the result of adjustment at the EEPROM by referencing the information of EEPROM WRITE.
⑤ Write the result of adjustment at the Data file by referencing the information of CARD WRITE.
<How to adjust>
a...Prepare AE TESTER that can be test up to LV 13.
b...Attach the camera to the AE TESTER.