<Description of TXT file>
When modify the program, use the Memo Pad of Windows and save it as "STS3105ADJ.txt"
Use only section related to each adjustment.
//////////////////////////////////////////////////////////
// PROJECT : STS3-105
// PROCESS : PM Batch Test 8
// DATE : 2007.02.15
/////////////////////////////////////////////////////////
//======================================#0. adj control
setting
adj_control check_process_id 65535
adj_control set_process_id 65534
adj_control save_e2prom 1
adj_control save_data_file 1
adj_control save_process_pass 1
adj_control batch 1
adj_control osd_delay 0
adj_control signal 100
//======================================#1. OB
delay 5
mode program
adj_ob preview_agc 96
adj_ob preview_target_rgb 0 0 0
adj_ob preview_luma_min_max 1500 4000
adj_ob capture_agc 96
adj_ob capture_target_rgb 0 0 0
adj_ob capture_luma_min_max 1500 4000
adj_ob run
//delay 5
//adj_control signal 100
79