Installing The Worm Pulley And Mechanism Belt; Replacing The Thermal Fuse Assembly - Kodak EKTAGRAPHIC III AM Service Manual

Kodak projector user manual
Hide thumbs Also See for KODAK EKTAGRAPHIC III AM:
Table of Contents

Advertisement

Installing the WORM PULLEY and MECHANISM BELT

Important
When installing the FAN and MECHANISM BELTS, install the MECHANISM BELT on the small MOTOR PULLEY,
and the FAN BELT on the large MOTOR PULLEY.
[1] Do the replacement procedure for the WORM PULLEY and MECHANISM BELT in reverse order.

Replacing the THERMAL FUSE ASSEMBLY

Warning
Dangerous Voltage
[1] Disconnect the main power.
[2] Do the replacement procedure for the LOWER HOUSING ASSEMBLY.
[3] Cut and remove the necessary WIRE TIES.
[4] Remove the black wire from the THERMAL FUSE ASSEMBLY on the POWER SWITCH.
[5] Remove the gray wire from the THERMAL FUSE ASSEMBLY from the POWER CORD.
[6] Loosen the Torx SCREW on the PREHEAT DUCT approximately half way.
[7] Pull the THERMAL FUSE ASSEMBLY out of hole of the LOWER LIGHT BAFFLE ASSEMBLY.
SM4530-1 – 30APR96
FAN BELT
MECHANISM BELT
Replacements and Installations
A091_4015BCA
A091_4015BA
9