Installing the MOTOR

Important
When installing the FAN and MECHANISM BELTS, install the MECHANISM BELT on the small MOTOR PULLEY,
and the FAN BELT on the large MOTOR PULLEY.
[1] Do the replacement procedure for the MOTOR in reverse order.

Replacing the WORM PULLEY and MECHANISM BELT

SCREW
A091_4017GCA
A091_4017GA
8
FAN BELT
Dangerous Voltage
WORM PULLEY
[1] Disconnect the main power.
[2] Do the replacement procedure for the LOWER
[3] Do the replacement procedure for the MOTOR
[4] Remove the Torx SCREW (on N.P. models) (or
[5] Move the TAB on the WORM PULLEY
[6] Remove the WORM PULLEY ASSEMBLY and
MECHANISM
BELT
MECHANISM BELT
Warning
HOUSING ASSEMBLY.
except do not disconnect the wires from the
MOTOR.
Hex SCREW on Painted Models) from the WORM
PULLEY ASSEMBLY.
ASSEMBLY out.
MECHANISM BELT.