U-Control operation and setup — advanced
Figure 101
U-Control system types and preset parameters
System type
8-character
Fan-coil
FAN-COIL
Finned tube baseboard
FIN BASE
Cast iron baseboard
IRN BASE
Cast iron radiators
RADIATOR
Radiant – slab on grade
RAD SLAB
Radiant – thin slab
RAD SLAB
Radiant – below floor
RADFLOOR
(staple up)
Radiant – above floor
RADFLOOR
(sleeper system)
Custom
CUSTOM
DHW – system
DOMESTIC
DHW – direct
DOMESTIC
ADVANCED SETUP –
CIRCULATOR EXERCISING
1.
For each circulator, select whether you want the U-Control to
automatically start the circulator and run for 10 seconds for each
72-hour period of inactivity.
Part number 550-100-090/0809
— Boiler Manual
Display
Preset temperatures
3-char
Max Target
Outdoor Temp
Temp
for Max Target
FCL
190
FTB
180
CIB
180
CIR
180
RSG
120
RTS
140
RSU
160
RAF
140
CUS
190
DHW
190
DHW heating ignores outdoor reset and
DHW
190
Min Target
Outdoor Temp
Temp
for Min Target
0
140
70
0
130
70
0
120
70
0
120
70
0
80
70
0
80
70
0
90
70
0
90
70
0
70
70
warm weather shutdown
ADVANCED SETUP –
FREEZE PROTECTION CIRCULATORS
1.
This function automatically fires the boiler at low fire
and starts the circulators chosen if the heat exchanger
sensor detects a temperature less than 40 °F. The circula-
tors turn off when the temperature rises above 45 °F.
ADVANCED SETUP –
MAINTENANCE INFO
1.
Use this section to enter contractor's information and
to enter an automatic notice for maintenance (default
is 12 months). Because this shows on the display, it is an
automatic means of notifying the homeowner of need
for scheduled maintenance by the technician. Update
the screen reminder to reset for the next maintenance
date.
(continued)
Note
• Does not pass along Add'l Heat Demand
• U-Control modulates to system tempera-
ture sensors
• U-Control modulates to boiler temperature
sensors
• Does not pass along Add'l Heat Demand