Download Print this page
Weil-McLain Ultra Series 3 Quick Start Manual
Weil-McLain Ultra Series 3 Quick Start Manual

Weil-McLain Ultra Series 3 Quick Start Manual

Gas fired water boilers series 3
Hide thumbs Also See for Ultra Series 3:

Advertisement

Gas-fired water boilers – Series 3
Featuring
Flexibility
Installation guide and material checklists
Series 3
This guide must only be used by a qualified heating installer/service technician. Read all instructions, including the boiler manual
and all other information shipped with the boiler, before installing. Perform steps in the order given. Failure to comply could result
in severe personal injury, death or substantial property damage.

Advertisement

loading

Summary of Contents for Weil-McLain Ultra Series 3

  • Page 1 Gas-fired water boilers – Series 3 Featuring Flexibility Installation guide and material checklists Series 3 This guide must only be used by a qualified heating installer/service technician. Read all instructions, including the boiler manual and all other information shipped with the boiler, before installing. Perform steps in the order given. Failure to comply could result in severe personal injury, death or substantial property damage.
  • Page 2: Quick Start

    QUICK-START QUICK-START (Follow all instructions in Boiler manual) START-UP, ADJUST & TEST BEFORE INSTALLING . . . • Follow the boiler manual instructions to clean the system • Make sure there is enough clearance for the boiler and all if needed, then fill and check water chemistry. water, gas and air piping.
  • Page 3 Vent / air pipe size options (PVC sizes): Ultra-80, 105: 2" or 3” Ultra-155: 3" Ultra-230: 3" or 4” Ultra-299, 399: 4” Sidewall with Sidewall with Sidewall with Vertical Vertical Weil-McLain Separate Pipes 3” Concentric Pipe 3” Concentric Pipe Separate Pipes termination termination termination termination termination...
  • Page 4 The derate ranges up to 10% for the W-M P/N Items required for: ✔ Ultra-80 at 100 feet or 15% for the Ultra-105 at 100 feet. Sidewall with Weil-McLain Plate Pipe and fittings — Plastic • W-M sidewall term. kit 3"...
  • Page 5: Water Piping

    WATER PIPING MATERIAL CHECKLIST (see boiler manual for details) RETURN TO PAGE 2 S e n s Do not exceed S y s t 12 inches apart S e n s S y s t D H W G a s D H W Typical piping, zone-valve zoning The circulator supplied with the boiler (...
  • Page 6 Use only antifreeze listed in Ultra boiler manual as suit- System and zone piping able for use with Ultra Gas boilers (antifreeze is available from Weil-McLain) — Ask your Weil-McLain distributor for System circulator and zone circulators (or zone valves) information or visit us online at www.weil-mclain.com to Pipe, valves and fittings for system and zone piping review Ultra literature for recommendations.

This manual is also suitable for:

Ultra-80Ultra-105Ultra-155Ultra-230Ultra-299Ultra-399