System Control System Adjustment; Initialization Of D, E, F, 7 Page Data; Servo Adjustment; Cap Fg Offset Adjustment (Vc-272 Board) - Sony Handycam CCD-TRV107 Service Manual

Hi8 video camera recorder
Hide thumbs Also See for Handycam CCD-TRV107:
Table of Contents

Advertisement

3-2. SYSTEM CONTROL SYSTEM ADJUSTMENT

1. Initialization of D, E, F, 7 Page Data

If the D, E, F, 7 page data is erased due to some reason, perform "1-
2. INITIALIZATION OF D, E, F, 7 PAGE DATA", of "5-1.
CAMERA SECTION ADJUSTMENT"

3-3. SERVO ADJUSTMENT

1. CAP FG Offset Adjustment (VC-272 board)

Set the Cap FG signal duty cycle to 50% to establish an appropriate
capstan servo. If deviated, the uneven rotation of capstan and noise
can occur in the LP mode.
Mode
Camera recording (SP mode)
Subject
Arbitrary
Measurement Point
CAP FG (Pin 4 of CN713)
Measuring Instrument
Oscilloscope
Adjustment Page
F
Adjustment Address
59
Specified value
Duty = 50 ± 1 %
Adjusting method:
Order Page Address Data
1
0
01
01
2
6
01
81
3
6
02
4
6
01
00
5
6
0
01
00
Center of movement
A
B
Fig. 5-3-4.
Procedure
Set the data.
Set the data, and press PAUSE
button.
Check that the data changes to
"01".
Set the data, and press PAUSE
button.
Check that Duty of CAP FG signal
satisfies the specified value. If not,
repeat steps 2 to 5.
Set the data.
Duty = A/B × 100 [%]
CCD-TRV107/TRV108/TRV308/TRV408/TRV608

2. Switching Position Adjustment (VC-272 board)

If deviated in this case causes switching noise or jitter on the played
back screen.
Mode
Signal
Measurement Point
Measuring Instrument
Adjustment Page
Adjustment Address
Specified Value
Adjusting Method:
Order Page Address Data
1
0
01
2
F
20
3
F
5A
4
F
5A
5
F
5B
6
F
5B
7
F
20
8
0
01
CH1
CH2
Enlargement
CH1
CH2
5-33
Playback
Alignment tape:
For tracking adjustment
(WR5-1NP)
CH1: SWP (Pin 5 of CN713)
CH2: PB RF (Pin 9 of CN713)
Oscilloscope
F
5A, 5B
t1 = 0 ± 10 µsec
Procedure
01
Set the data.
40
Set the data, and press PAUSE
button.
Change the data and minimize
"t1". (Coarse adjustment)
Press PAUSE button
Change the data and adjust so
that the switching position (t1)
becomes the specified value.
(Fine adjustment)
Press PAUSE button
00
Set the data, and press PAUSE
button.
00
Set the data.
t1=0 ± 10 µsec
Fig. 5-3-5.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents