6

Installation

6.1

Requirements for the installation room

DANGER
– Install the heating system in a frost-free
room.
– Do not store any flammable materials or
liquids in the immediate vicinity of the boiler.
– Never use any chlorinated detergents or
halogenated hydrocarbons (e. g. in
spraycans, solvents and detergents, paints,
adhesives).
– Do not allow too much dust to collect on the
boiler.
6.2

Fitting the boiler

Observe the installation clearances of the combustion air/
flue gas system.
NOTICE
– To protect the connection orifice you must
not remove the styrofoam bottom panel.
– Do not lift the boiler by the drawer.
– Do not remove the transport safety clamps
(see fig. 6) from the drawer at this time.
– Protect the boiler and the combustion
air/flue gas orifice against pollution during
installation.
 Remove the packaging materials and dispose of them.
 Use the mounting template to mark the drill holes.
 Install the wall bracket taking into account the necessary
service clearances.
 Remove the transport safety clamps (fig. 6).
Logamax plus GB142-24/30/45/60 - We reserve the right to make any changes due to technical modifications!
Fig. 6
Removing the transport safety clamps